This study presents an attempt to compare individualised palliative treatment absorbed doses, by planar images data and Monte Carlo simulation, in two in vivo treatment cases, one of bone metastases and the other of liver lesions. Medical Internal Radiation Dose schema was employed to estimate the absorbed doses. Radiopharmaceutical volume distributions and absorbed doses in the lesions as well as in critical organs were also calculated by Monte Carlo simulation. Individualised planar data calculations remain the method of choice in internal dosimetry in nuclear medicine, but with the disadvantage of attenuation and scatter corrections lack and organ overlay. The overall error is about 7 % for planar data calculations compared with that using Monte Carlo simulation. Patient-specific three-dimensional dosimetric calculations using single-photon emission computed tomography with a parallel computed tomography study is proposed as an accurate internal dosimetry with the additional use of dose-volume histograms, which express dose distributions in cases with obvious inhomogeneity.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.