Monte Carlo simulations have been used to study the influence of the magnetic field on ion impact at the cathode surface of a sputtering magnetron discharge. The ion parameters (energy, incident angle at the cathode and transit time) have been investigated under four magnetic field strengths and two pressures (1 and 10 Pa). It has been confirmed that the magnetic field has little influence on ion motion. Also, it was found that the magnetic field's influences on ion parameters are given through its influence on electron motion, namely on the ionization site, which is most important in determining the ion energy and transit time. It is proposed that, taking into consideration both the ion energy and the transit time, the appropriate ionization site is the edge of the cathode fall region.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.