Optimization of the mass sensitivity of wafer bonded resonant gravimetric capacitive micromachined ultrasonic transducers (CMUTs) is presented. Gas phase sensors based on resonant gravimetric CMUTs have previously been demonstrated. An important figure of merit of these sensors is the sensitivity which, for typical CMUT geometries, is increased by decreasing the radius of the CMUT cell. This paper investigates how to minimize the radius of CMUT cells fabricated using the wafer bonding process. The design and process parameters affecting the radius of the CMUT and hereby the sensitivity are studied through numerical simulations and atomic force microscopy measurements. An excellent fit was obtained between the simulations and measured profiles with a low relative error of ≤ 5%, thus validating the simulation model. Two types of CMUTs are designed and fabricated using the design and process rules determined herein, with experimentally determined mass sensitivities of 0.46 Hz/ag and 0.44 Hz/ag, respectively. The two CMUT devices have cavities made using the local oxidation of silicon (LOCOS) and reactive ion etching (RIE) process. For the LOCOS process, it was found that the smallest radius can be obtained by choosing a Si 3 N 4 oxidation mask and lowering the pad SiO 2 thickness, vacuum gap height, and Si bump height. For the RIE process, the vertical dimensions do not influence the horizontal dimensions and consequently, equivalent rules do not exist.
Abstract-This paper presents an experimental study of the acoustic performance of Capacitive Micromachined Ultrasonic Transducers (CMUTs) as function of plate dimensions. The objective is to increase the output pressure without decreasing the pulse-echo signal. The CMUTs are fabricated with a LOCOS process, followed by direct wafer fusion bonding to a SiliconOn-Insulator (SOI) wafer. In this way, the plate thickness is determined by the SOI wafer device layer thickness, resulting in CMUTs with plate thicknesses of 2, 9.3 and 15 µm. The corresponding radii and gap heights resulting in an immersion frequency of 5 MHz and a pull-in voltage of 200 V are obtained using finite element analysis. Hydrophone and plane reflector measurements are used to assess the acoustic performance. Increasing the plate thickness from 2 µm to 15 µm decreases the pulse-echo bandwidth from >100% to 30%. A maximum in both peak-to-peak output pressure and pulse-echo signal is obtained for the 9.3 µm plate, which still has a moderate pulseecho bandwidth of 60%. The 9.3 µm plate results in a 1.9 times higher peak-to-peak output pressure and a 3.6 times higher pulse-echo signal compared to the 2 µm plate. By adjusting the plate dimensions of a CMUT it is possible to optimize its acoustic performance for medical imaging applications, including visualization of deeper structures in the body, as well as nonlinear imaging such as tissue harmonic imaging.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.