Compared with high tibial osteotomy and total knee arthroplasty, the authors found a simpler surgical procedure, partial fibular osteotomy, could effectively relieve knee pain and also correct the varus deformity for patients with medial compartment knee osteoarthritis (OA). From January 1996 to April 2012, a total of 156 patients with medial compartment OA were treated by proximal fibular osteotomy in the authors' hospital. A 2-cm-long section of fibula was resected 6 to 10 cm below the fibular head. A total of 110 patients with follow-up of more than 2 years were included in the study, including 34 males and 76 females with an average age of 59.2 years. Anteroposterior and lateral weight-bearing radiographs, the femorotibial angle (FTA) and lateral joint space, and the American Knee Society Score (KSS) and the visual analog scale (VAS) score of the knee joint were evaluated preoperatively and at final follow-up, respectively. At final follow-up, mean FTA and lateral joint space were 179.4°±1.8° and 6.9±0.7 mm, respectively, which were significantly smaller than those measured preoperatively (182.7°±2.0° and 12.2±1.1 mm, respectively; both P<.001). Mean KSS at final follow-up was 92.3±31.7, significantly higher than the mean preoperative score of 45.0±21.3 (P<.001). Mean VAS score and interquartile range were 2.0 and 2.0, significantly lower than the preoperative data (7 and 1.0, respectively; P<.001). The authors found that proximal fibular osteotomy can significantly improve both the radiographic appearance and function of the affected knee joint and also achieve long-term pain relief. This procedure may be an alternative treatment option for medial compartment OA.
Nano-hydroxyapatite (n-HA) slurry was synthesized at normal pressure, and (Cu2+, Zn2+)-bearing nano-hydroxyapatite (Cu-Zn-HA) was prepared by ion exchange reaction in water medium. The properties of n-HA and Cu-Zn-HA were characterized by AAS, TEM, XRD and FTIR. The results of XRD analysis indicate that Cu2+ and Zn2+ can occupy Ca2+ sites and enter the crystal lattice of hydroxyapatite. Through the antibacterial experiments, it was found that Cu-Zn-HA had better antibacterial ability on Escherichia coli (E. coli) and Staphylococcus aureus (S. aureus). After heat treatment at 400°C for an hour, the materials still had good antibacterial effect. The accelerated aging method was employed to test antibacterial durability of the material and the results indicated that the durability was good. The results of the security assessment, including skin stimulation test
of rabbit, acute toxicity test by stomach filling and the micronucleus test in bone marrow polychromatic erythrocytes of mice, showed that the security of the material was excellent.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.