Background The oXiris is a novel filter for continuous renal replacement therapy (CRRT) featuring an adsorption coating to adsorb endotoxins and remove inflammatory mediators. Given that no consensus has been reached on its potential benefits in treating sepsis, a meta-analysis was conducted to assess its impact on the clinical outcomes of this patient population. Methods Eleven databases were retrieved to find relevant observational studies and randomized controlled trials. The Newcastle–Ottawa Scale and the Cochrane Risk of Bias Tool were used to assess the quality of the included studies. The Grading of Recommendations, Assessment, Development, and Evaluation (GRADE) process was employed to assess the certainty of evidence. The 28-day mortality was the primary outcome. Secondary outcomes were 7-, 14-, and 90-day mortality, length of intensive care unit (ICU) and hospital stay, ICU and hospital mortality, norepinephrine (NE) dose, interleukin-6 (IL-6) and lactate levels, and Sequential Organ Failure Assessment (SOFA) score. Results The meta-analysis, pooling data from 14 studies, involving 695 patients, showed significant reductions in 28-day mortality [odds ratio (OR) 0.53; 95% confidence interval (CI) 0.36–0.77, p = 0.001] and length of ICU stay [weighted mean difference (WMD) − 1.91; 95% CI − 2.56 to − 1.26, p < 0.001)] in patients with sepsis using the oXiris filter compared to other filters. Besides, the SOFA score, NE dose, IL-6 and lactate levels, and 7- and 14-day mortalities were lower in the oXiris group. However, the 90-day mortality, ICU and hospital mortality, and length of hospital stay were comparable. The quality assessment of the ten observational studies indicated intermediate to high quality (average Newcastle–Ottawa score: 7.8). However, all four randomized controlled trials (RCTs) had an unclear risk of bias. The evidence for all outcomes had a low or very low level of certainty because the original study design was mainly observational studies and the RCTs included had an unclear risk of bias and a small sample size. Conclusion The treatment with the oXiris filter during CRRT in sepsis patients may be associated with lower 28-, 7-, and 14-day mortalities, lactate levels, SOFA score, NE dose, and shorter length of ICU stay. However, due to the low or very low quality of evidence, the effectiveness of oXiris filters was still uncertain. Besides, no significant difference was observed for the 90-day mortality, ICU and hospital mortality, and length of hospital stay.
Introduction:The incidence, mortality, and treatment costs of sepsis are high and, thus, present a major challenge for critical care medicine. Our previous studies suggest that intestinal metabolite granisetron has a potential therapeutic effect on sepsis. Granisetron is a clinically widely used antiemetic, which is safe, inexpensive, and reliable. However, its value in the treatment of sepsis remains unclear. This study aims to explore the efficacy and safety of granisetron in the treatment of sepsis.Methods and analysis:A single-center, single-blind, randomized, controlled clinical trial will be conducted on 154 patients with sepsis. Patients who meet sepsis 3.0 diagnostic criteria, aged ≥18 and ≤80 years, with PCT ≥ 2 ng/mL will be recruited. Patients will be randomized to receive intravenous granisetron 3 mg every 8 hours (n = 77) or an equal volume of normal saline (n = 77) for a treatment period of 4 days or to ICU discharge. The primary outcome is 28-day all-cause mortality. Secondary outcome measures include requirements for organ function support, changes of organ function, changes in infection biomarkers, changes in inflammatory and immune biomarkers, and the proportion of new organ failure. Adverse events and serious adverse events also will be observed closely.Ethics and dissemination:The study was approved by the Clinical Ethics Committee of Zhujiang Hospital of Southern Medical University (2018-ZZJHZX-009). The trial results will be disseminated at national and international conferences and through peer-reviewed journal.Trial registration:NCT03924518.URL: www.clinicaltrials.gov.Protocol date:1 May 2019. version 2.1.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.