The aim of Working Group 4 has been to develop and disseminate best practice in undertaking and reporting assessments, and to identify needs for methodologic development.
Patient doses for a few common fluoroscopy-guided procedures in interventional radiology (IR) (excluding cardiology) were collected from a few radiological departments in 13 European countries. The major aim was to evaluate patient doses for the basis of the reference levels. In total, data for 20 procedures for about 1300 patients were collected. There were many-fold variations in the number of IR equipment and procedures per population, in the entrance dose rates, and in the patient dose data (total dose area product or DAP, fluoroscopy time and number of frames). There was no clear correlation between the total DAP and entrance dose rate, or between the total DAP and fluoroscopy time, indicating that a number of parameters affect the differences. Because of the limited number of patients, preliminary reference levels were proposed only for a few procedures. There is a need to improve the optimisation of IR procedures and their definitions and grouping, in order to account for their different complexities.
New developments in dual energy X-ray absorptiometry (DEXA) imaging technology [fan beam and cone beam (CB)] result in higher exposure levels, shorter scan times, increased patient throughput and increased shielding requirements. This study presents the results of a European survey detailing the number and location of DEXA systems in SENTINEL partner states and the QA (quality assurance) currently performed by physicists and operators in these centres. The results of a DEXA equipment survey based on an in-house developed QA protocol are presented. Measurements show that the total effective dose to the patient from a spine and dual femur DEXA examination on the latest generation DEXA systems is comparable with a few microSv at most. Scatter measurements showed that the use of a mobile lead screen for staff protection was necessary for fan and CB systems. Scattered dose from newer generation systems may also exceed the exposure limits for the general public so structural shielding may also be required. Considerable variation in the magnitude and annual repeatability of half value layer was noted between different models of DEXA scanners. A comparative study of BMD (bone mineral density) accuracy using the European Spine Phantom highlighted a deviation of up to 7% in BMD values between scanners of different manufacturers.
Objective:Medical ethics has a tried and tested literature and a global active research community. Even among health professionals, literate and fluent in medical ethics, there is low recognition of radiation protection principles such as justification and optimization. On the other hand, many in healthcare environments misunderstand dose limitation obligations and incorrectly believe patients are protected by norms including a dose limit. Implementation problems for radiation protection in medicine possibly flow from apparent inadequacies of the International Commission on Radiological Protection (ICRP) principles taken on their own, coupled with their failure to transfer successfully to the medical world. Medical ethics, on the other hand, is essentially global, is acceptable in most cultures, is intuitively understood in hospitals, and its expectations are monitored, even by managements. This article presents an approach to ethics in diagnostic imaging rooted in the medical tradition, and alert to contemporary social expectations. ICRP and the International Radiation Protection Association (IRPA), both alert to growing ethical concerns, organized a series of consultations on ethics for general radiation protection in the last few years.Methods:The literature on medical ethics and implicit ICRP ethical values were reviewed qualitatively, with a view to identifying a system that will help guide contemporary behaviour in radiation protection of patients. Application of the system is illustrated in six clinical scenarios. The proposed system is designed, as far as is possible, so as not to be in conflict with the conclusions emerging from the ICRP/IRPA consultations.Results and conclusion:A widely recognized and well-respected system of medical ethics was identified that has global reach and claims acceptance in all cultures. Three values based on this system are grouped with two additional values to provide an ethical framework for application in diagnostic imaging. This system has the potential to be robust and to reach conclusions that are in accord with contemporary medical, social and ethical thinking. The system is not intended to replace the ICRP principles. Rather, it is intended as a well-informed interim approach that will help judge and analyse situations that arouse ethical concerns in radiology. Six scenarios illustrate the practicality of the value system in alerting one to possible deficits in practice.Advances in knowledge:Five widely recognized values and the basis for them are identified to support the contemporary practice of diagnostic radiology. These are essential to complement the widely used ICRP principles pending further development in the area.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.