Heritage masonry buildings are particularly vulnerable to earthquakes because they are deteriorated and damaged, they were built with materials with low resistance, they are heavy and the connections between the various structural components are often insufficient. The present work details a simplified method of seismic assessment of large span masonry structures that was applied to a database of 44 monuments in Italy, Portugal and Spain, providing lower bound formulas for different simplified geometrical indexes. Subsequently, the proposed thresholds are validated with data from the 2010–2011 Canterbury earthquakes, which includes 48 stone and clay brick masonry churches. Finally, fragility curves that can be used to estimate the damage as a function of the peak ground acceleration (PGA) are also provided
As part of the ‘Project Masonry’ Recovery Project funded by the New Zealand Natural Hazards Research Platform, commencing in March 2011, an international team of researchers was deployed to document and interpret the observed earthquake damage to masonry buildings and to churches as a result of the 22nd February 2011 Christchurch earthquake. The study focused on investigating commonly encountered failure patterns and collapse mechanisms. A brief summary of activities undertaken is presented, detailing the observations that were made on the performance of and the deficiencies that contributed to the damage to approximately 650 inspected unreinforced clay brick masonry (URM) buildings, to 90 unreinforced stone masonry buildings, to 342 reinforced concrete masonry (RCM) buildings, to 112 churches in the Canterbury region, and to just under 1100 residential dwellings having external masonry veneer cladding. In addition, details are provided of retrofit techniques that were implemented within relevant Christchurch URM buildings prior to the 22nd February earthquake and brief suggestions are provided regarding appropriate seismic retrofit and remediation techniques for stone masonry buildings.
The present work entails a statistical analysis of the data collected for 112 churches in the affected region, including in situ damage observed by the authors and the structural assessment classification assigned by local authorities. The seismic performance of these churches is discussed and compared with both the structural classifications used in Italy, where a specific survey form for churches is used, and with the building damage classifications assigned by the local authorities.
The paper presents a numerical study for the seismic assessment of the St James Church in Christchurch, New Zealand affected by the recent 2011 earthquake and subsequent aftershocks. The structural behavior of the Church has been evaluated using the finite element modelling technique, in which the nonlinear behavior of masonry has been taken into account by proper constitutive assumptions. Two numerical models were constructed, one incorporating the existing structural damage and the other considering the intact structure. The validation of the numerical models was achieved by the calibration of the damaged model according to dynamic identification tests carried out in situ after the earthquake. Non-linear pushover analyses were carried out on both principal directions demonstrating that, as a result of the seismic action, the Church can no longer be considered safe. Pushover analysis results of the undamaged model show reasonable agreement with the visual inspection performed in situ, which further validates the model used. Finally, limit analysis using macro-block analysis was also carried out to validate the main local collapse mechanisms of the Church.
Summary Several factors influence the behaviour of infilled frames, which have been a subject of research in the past with moderate success. The new generation of European design standards imposes the need to prevent brittle collapse of the infills and makes the structural engineer accountable for this requirement, yet it fails to provide sufficient information for masonry infills design. Therefore, the present work aims at understanding the seismic behaviour of masonry infill walls within reinforced concrete frames, using both unreinforced and reinforced solutions (bed joint reinforcement and reinforced plaster). For this purpose, three reinforced concrete buildings with different infill solutions were constructed at a scale of 1:1.5, all with the same geometry, and were tested on the shaking table of the National Laboratory for Civil Engineering, Portugal. All solutions performed adequately for the design earthquake, with no visible damage. Still, the experimental tests show that the double‐leaf‐unreinforced infill walls underperformed during a large earthquake, collapsing out of plane by rotating as rigid bodies with multiple configurations. Also the reinforced concrete buildings collapsed, because of the adverse interaction with the infill walls. The infill walls with bed joint reinforcement and reinforced plaster did not collapse out of plane, because of their connection to the concrete frame, which is an essential requirement. Copyright © 2016 John Wiley & Sons, Ltd.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.