Purpose
Misinformation can have lasting impacts in the management and control of a public emergency. The purpose of this paper is to demonstrate how misinformation flows and how user characteristics can shape such flows in the context of a violent riot in Singapore.
Design/methodology/approach
The authors apply the two-step flow theory and discuss the mixed methods approach involving wrangling Twitter data and descriptive analysis to develop and analyse two corpuses of misinformation related to the riot.
Findings
The findings are mostly consistent with the two-step flow theory, in that misinformation flows to the masses from opinion leaders (as indicated by higher measures such as online social influence and followers/following ratio). In the presence of misinformation, tweets opposing such misinformation may not always come from opinion leaders.
Practical implications
The authors work furthers knowledge about how misinformation goes viral, which provides practical implications to help policymakers and scholars in understanding and managing the dynamics and pitfalls of misinformation during an emergency.
Originality/value
This paper tackles the problem of misinformation in public emergencies using a mixed methods approach and contributes to ongoing theoretical work on managing online misinformation especially in public emergencies and crises.
Objective: To ascertain the accuracy of 2 upper-arm blood pressure monitors, GE Carescape V100 Vital Signs and Omron HEM-9210T, used in a large, South-East Asian epidemiological cohort by the AAMI/ESH/ISO 81060-2:2018. Methods: 149 participants were recruited from the ongoing Health for Life in Singapore (HELIOS) Study in multi-ethnic Singapore. Results: 110 datasets were analysed. For criterion 1, the mean(SD) of differences for GE Carescape V100 was -3.5(7.4)/ -3.5(7.4) mmHg (systolic/diastolic), and -4.2(6.9)/ -4.2(6.9) mmHg (systolic/diastolic) for Omron HEM-9210T. For criterion 2, GE Carescape V100was -3.5(5.6) / -3.5(5.6) mmHg (systolic/diastolic), and -4.2(4.5) / -4.2(4.6) mmHg (systolic/diastolic) for Omron HEM-9210T. Conclusion: Both GE Carescape V100 Vital Signs and Omron HEM-9210T monitor passed the AAMI/ESH/ISO 81060-2:2018 validation standard.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.