High density 3D memory cell array using SGT (Surrounding Gate Transistor) on 3D IC is proposed. SGT with 4F 2 cell size shows uniform cell characteristics with a low resistive bit-line path on 3D IC. Parasitic bit-line capacitance of the structure can also be much lower compared to conventional 2D memory cell array or SGT cell array on bulk substrate, which is especially good for memory feature size at or below 10 nm cell node. A combination of 3D memory cell and 3D IC seems to be the ideal memory architecture for the low cost-per-bit of high density memories.
Background Human beings can enhance their distance running performance with the help of assistive devices. Although several such devices are available, they are heavy and bulky, which limits their use in everyday activities. In this study, we developed a lightweight running assistive device with a low-profile design. The device applies a flexion moment to the hip according to the hip extension within a specific range of motion to assist running. Methods A passive exosuit was fabricated using textile materials and elastic bands. The deformation of the suit was measured and compensated for in the design. The fabricated suit was tested on eight participants (age: 24.4 ± 3.8 y; height: 1.72 ± 0.05 m; weight: 74.5 ± 6.1 kg) who were instructed to run on a treadmill at a speed of 2.5 m/s. Through indirect calorimetry, the metabolic rate was measured for the no-suit condition and three band conditions. Variations in the spatiotemporal parameters were measured using a motion capture system and force-sensing resistors (FSRs). Results When using the fabricated device, seven out of the eight participants exhibited a reduced metabolic rate in at least one of the three band conditions. An average reduction of − 4.7 ± 1.4% (mean ± standard error of the mean (s.e.m.), two-sided paired t-test, p = 0.017) was achieved when using the best-fitting bands compared to the average of the two no-suit conditions. No statistically significant changes were observed in the spatiotemporal parameters, except for the stance duration in the medium assistance force condition. Conclusions The proposed passive exosuit, which has a low weight of 609 g and small extrusion of 2.5 cm from the body in standing posture, can reduce the metabolic rate during running. The proposed device can potentially be used every day owing to its low-profile design and low weight, thereby overcoming the limitations of existing portable devices targeting the hip joints.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.