BackgroundWe retrospectively assessed the clinical outcomes and investigated risk factors influencing retear after arthroscopic suture bridge repair technique for rotator cuff tear through clinical assessment and magnetic resonance arthrography (MRA).MethodsBetween January 2008 and April 2011, sixty-two cases of full-thickness rotator cuff tear were treated with arthroscopic suture bridge repair technique and follow-up MRA were performed. The mean age was 56.1 years, and mean follow-up period was 27.4 months. Clinical and functional outcomes were assessed using range of motion, Korean shoulder score, Constant score, and UCLA score. Radiological outcome was evaluated with preoperative and follow-up MRA. Potential predictive factors that influenced cuff retear, such as age, gender, geometric patterns of tear, size of cuff tear, acromioplasty, fatty degeneration, atrophy of cuff muscle, retraction of supraspinatus, involved muscles of cuff and osteolysis around the suture anchor were evaluated.ResultsThirty cases (48.4%) revealed retear on MRA. In univariable analysis, retear was significantly more frequent in over 60 years age group (62.5%) than under 60 years age group (39.5%; p = 0.043), and also in medium to large-sized tear than small-sized tear (p = 0.003). There was significant difference in geometric pattern of tear (p = 0.015). In multivariable analysis, only age (p = 0.036) and size of tear (p = 0.030) revealed a significant difference. The mean active range of motion for forward flexion, abduction, external rotation at the side and internal rotation at the side were significantly improved at follow-up (p < 0.05). The mean Korean shoulder score, Constant score, and UCLA score increased significantly at follow-up (p < 0.01). The range of motion, Korean shoulder score, Constant score, and UCLA score did not differ significantly between the groups with retear and intact repairs (p > 0.05). The locations of retear were insertion site in 10 cases (33.3%) and musculotendinous junction in 20 cases (66.7%; p = 0.006).ConclusionsSuture bridge repair technique for rotator cuff tear showed improved clinical results. Cuff integrity after repair did not affect clinical results. Age of over 60 years and size of cuff tear larger than 1 cm were factors influencing rotator cuff retear after arthroscopic suture bridge repair technique.
It has been suggested that the increased frequency of trigger finger (TF) after carpal tunnel release (CTR) may be caused by the volar migration of the flexor tendons at the wrist altering the tendon biomechanics at the A1 pulley. This hypothesis has not been validated. We performed pre- and post-operative ultrasonography (USG) on the affected wrists of 92 patients who underwent CTR. Pre-operative USG was performed in neutral with no tendon loading; post-operative USG was performed in neutral unloaded and in various positions of wrist flexion whilst loading the flexor tendons with gripping. The mean volar migration of the flexor tendons after CTR was 2.2 (SD 0.4) mm in the unloaded neutral position. It was 1.8 (SD 0.4) mm in patients who did not develop TF and 2.5 (SD 0.5) mm in those who did (p = 0.0067). In loaded wrist flexion, the mean volar migration of flexor tendons after CTR in patients who did not develop TF and those who did was 2.1 and 3.0 mm in 0° flexion; 3.2 and 3.9 mm in 15° flexion; 4.3 and 5.1 mm in 30° flexion; and 4.9 and 5.8 mm in 45° flexion, respectively. There were significant differences between patients with and without TF at each flexion angle. Our data indicate that patients with greater volar migration of the flexor tendons after CTR are more likely to develop TF. This conclusion supports the hypothesis that the occurrence of TF after CTR may be caused by the bowstringing effects of the flexor tendons.
The aims of this study were to assess the efficacy of a newly designed radiological technique (the radial groove view) for the detection of protrusion of screws in the groove for the extensor pollicis longus tendon (EPL) during plating of distal radial fractures. We also aimed to determine the optimum position of the forearm to obtain this view. We initially analysed the anatomy of the EPL groove by performing three-dimensional CT on 51 normal forearms. The mean horizontal angle of the groove was 17.8° (14° to 23°). We found that the ideal position of the fluoroscopic beam to obtain this view was 20° in the horizontal plane and 5° in the sagittal plane. We then intra-operatively assessed the use of the radial groove view for detecting protrusion of screws in the EPL groove in 93 fractures that were treated by volar plating. A total of 13 protruding screws were detected. They were changed to shorter screws and these patients underwent CT scans of the wrist immediately post-operatively. There remained one screw that was protruding. These findings suggest that the use of the radial groove view intra-operatively is a good method of assessing the possible protrusion of screws into the groove of EPL when plating a fracture of the distal radius.
BackgroundThis study examines the clinical and radiologic results of ceramic-on-ceramic total hip arthroplasties with regard to wear, osteolysis, and fracture of the ceramic after a minimum follow-up of six years.MethodsWe evaluated the results of a consecutive series of 148 primary ceramic-on-ceramic total hip arthroplasties that had been performed between May 2001 and October 2005 in 142 patients. The mean age was 57.2 years (range, 23 to 81 years). The mean follow-up period was 7.8 years (range, 6.1 to 10.1 years). Preoperative diagnosis was avascular necrosis in 77 hips (52%), degenerative arthritis in 36 hips (24.3%), femur neck fracture in 18 hips (12.2%), rheumatoid arthritis in 15 hips (10.1%), and septic hip sequelae in 2 hips (1.4%). Clinical results were evaluated with the Harris hip score, and the presence of postoperative groin or thigh pain. Radiologic analysis was done with special attention in terms of wear, periprosthetic osteolysis, and ceramic failures.ResultsThe mean Harris hip score improved from 58.3 (range, 10 to 73) to 92.5 (range, 79 to 100) on the latest follow-up evaluation. At final follow-up, groin pain was found in 4 hips (2.7%), and thigh pain was found in 6 hips (4.1%). Radiologically, all femoral stems demonstrated stable fixations without loosening. Radiolucent lines were observed around the stem in 25 hips (16.9%), and around the cup in 4 hips (2.7%). Endosteal new bone formation was observed around the stem in 95 hips (64.2%) and around the cup in 88 hips (59.5%). No osteolysis was observed around the stem and cup. There were 2 hips (1.4%) of inclination changes of acetabular cup, 2 hips (1.4%) of hip dislocation, 1 hip (0.7%) of ceramic head fracture, and 1 hip (0.7%) of squeaking. The Kaplan-Meier survival rate of the prostheses was 98.1% at postoperative 7.8 years.ConclusionsThe ceramic-on-ceramic total hip arthroplasty produced excellent clinical results and implant survival rates with no detectable osteolysis on a minimum six-year follow-up study. The ceramic-on-ceramic couplings could be a reasonable option of primary total hip arthroplasty for variable indications.
The study group who received 7-day continuous femoral nerve block after TKA showed superior analgesia and higher patient satisfaction during the hospital stay than those given 3-day continuous femoral nerve block. Despite the additional time, effort and cost to place and manage continuous femoral nerve catheters, the 7-day continuous femoral nerve block can be recommended as an effective and safe regional component of a multimodal analgesia strategy after TKA.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.