BackgroundImperfect sensitivity of interferon-γ release assay (IGRA) is a potential problem to detect tuberculosis. We made a thorough investigation of the factors that can lead to false negativity of IGRA.MethodsWe recruited 543 patients with new smear-positive pulmonary tuberculosis in Hanoi, Viet Nam. At diagnosis, peripheral blood was collected and IGRA (QuantiFERON-TB Gold In-Tube) was performed. Clinical and epidemiological information of the host and pathogen was collected. The test sensitivity was calculated and factors negatively influencing IGRA results were evaluated using a logistic regression model in 504 patients with culture-confirmed pulmonary tuberculosis.ResultsThe overall sensitivity of IGRA was 92.3% (95% CI, 89.6%–94.4%). The proportions of IGRA-negative and -indeterminate results were 4.8% (95% CI, 3.1%–7.0%) and 3.0% (95% CI, 1.7%–4.9%). Age increased by year, body mass index <16.0, HIV co-infection and the increased number of HLA-DRB1*0701 allele that patients bear showed significant associations with IGRA negativity (OR = 1.04 [95% CI, 1.01–1.07], 5.42 [1.48–19.79], 6.38 [1.78–22.92] and 5.09 [2.31–11.22], respectively). HIV co-infection and the same HLA allele were also associated with indeterminate results (OR = 99.59 [95% CI, 15.58–625.61] and 4.25 [1.27–14.16]).ConclusionsAging, emaciation, HIV co-infection and HLA genotype affected IGRA results. Assessment of these factors might contribute to a better understanding of the assay.
BackgroundGranulysin (GNLY) is produced by human lymphocyte subpopulations and exhibits antimicrobial activity against Mycobacterium tuberculosis. We examined the association between GNLY levels in blood and latent tuberculosis (TB) infection.MethodsLatency of TB infection among Vietnamese healthcare workers was estimated using interferon-gamma release assays (IGRA), and serum GNLY concentrations were measured using enzyme-linked immunosorbent assays. The levels of GNLY expression in whole blood and the presence of GNLY alleles with the exon-4 polymorphism rs11127 were also determined using PCR-based methods.ResultsAmong 109 study participants, 41 (37.6 %) were IGRA positive and had significantly lower serum GNLY concentrations compared with IGRA-negative participants (adjusted mean, 95 % confidence interval; 2.03, 1.72–2.44 vs. 2.48, 2.10–2.92 ng/ml, P = 0.0127; analysis of covariance). Serum GNLY concentrations and TB antigen-stimulated interferon-gamma values were weakly inversely correlated (r = −0.20, P = 0.0333). Serum GNLY concentrations varied with GNLY genotypes even after adjustment for gender and age (adjusted P = 0.0015) and were moderately correlated with GNLY expression in blood cells (r = 0.40, P < 0.0001). In subsequent analyses, low serum GNLY concentrations were significantly associated with IGRA status (adjusted odds ratio and 95 % confidence interval, 0.55 and 0.31–0.98, respectively), although GNLY genotype and mRNA levels were not.ConclusionsDecreased GNLY, presumably at the protein level, is linked to the immunological condition of latent TB infection.
It was demonstrated that a majority of active TB patients showing negative IGRA results did not regain sufficient levels of immune responsiveness despite successful treatment.
BackgroundWhen a test for diagnosis of infectious diseases is introduced in a resource-limited setting, monitoring quality is a major concern. An optimized design of experiment and statistical models are required for this assessment.MethodsInterferon-gamma release assay to detect tuberculosis (TB) infection from whole blood was tested in Hanoi, Viet Nam. Balanced incomplete block design (BIBD) was planned and fixed-effect models with heterogeneous error variance were used for analysis. In the first trial, the whole blood from 12 donors was incubated with nil, TB-specific antigens or mitogen. In 72 measurements, two laboratory members exchanged their roles in harvesting plasma and testing for interferon-gamma release using enzyme linked immunosorbent assay (ELISA) technique. After intervention including checkup of all steps and standard operation procedures, the second trial was implemented in a similar manner.ResultsThe lack of precision in the first trial was clearly demonstrated. Large within-individual error was significantly affected by both harvester and ELISA operator, indicating that both of the steps had problems. After the intervention, overall within-individual error was significantly reduced (P < 0.0001) and error variance was no longer affected by laboratory personnel in charge, indicating that a marked improvement could be objectively observed.ConclusionBIBD and analysis of fixed-effect models with heterogeneous variance are suitable and useful for objective and individualized assessment of proficiency in a multistep diagnostic test for infectious diseases in a resource-constrained laboratory. The action plan based on our findings would be worth considering when monitoring for internal quality control is difficult on site.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.