A sensitive method based on high-performance liquid chromatography–tandem mass spectrometry (LC–MS/MS) has been developed for the simultaneous determination of folic acid (FA) and its active metabolite, 5-methyltetrahydrofolic acid (5-M-THF), in human plasma. The analytes were extracted from plasma with methanol solution containing 10 mg/mL of 2-mercaptoethanol and 0.025% (v/v) ammonium hydroxide. FA and 5-M-THF were more stable after the addition of 2-mercaptoethanol and ammonium hydroxide in the sample preparation procedures of this study than they were in the previously published methods. Chromatographic separation was performed on a Hedera ODS-2 column using a gradient elution system of acetonitrile and 1 mM ammonium acetate buffer solution containing 0.6% formic acid as mobile phase. LC–MS/MS was carried out with an ESI ion-source and operated in the multiple reaction monitoring (MRM) mode. The assay was linear over the concentration ranges of 0.249–19.9 ng/mL for FA, and 5.05–50.5 ng/mL for 5-M-THF. The developed LC–MS/MS method offers increased sensitivity for quantification of FA and 5-M-THF in human plasma and was applicable to a pharmacokinetic study of FA and 5-M-THF.
Amoxicillin (AMO) degrades in plasma at room temperature and readily undergoes hydrolysis by the plasma amidase. In this paper, a novel, rapid and sensitive LC-MS/MS method operated in segmental and multiple reaction monitoring has been developed for the simultaneous determination of amoxicillin and ambroxol in human plasma. The degradation of amoxicillin in plasma was well prevented by immediate addition of 20 μL glacial acetic acid to 200 μL aliquot of freshly collected plasma samples before storage at -80°C. The sensitivity of the method was improved with segmental monitoring of the analytes, and lower limits of quantitation of 0.5 ng/mL for ambroxol and 5 ng/mL for amoxicillin were obtained. The sensitivity of our method was five times better than those of the existing methods. Furthermore, the mass response saturation problem with amoxicillin was avoided by diluting the deproteinized plasma samples with water before injection into the LC-MS/MS system. The method was successfully employed in a pharmacokinetic study of the compound amoxicillin and ambroxol hydrochloride tablets.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.