A new electrocatalyst, palladium nanoparticle-single-walled carbon nanotube (Pd-SWNTs) hybrid nanostructure, for the nonenzymatic oxidation of glucose was developed and characterized by X-ray diffraction (XRD) and the transmission electron microscope (TEM). The hybrid nanostructures were prepared by depositing palladium nanoparticles with average diameters of 4-5 nm on the surface of single-walled carbon nanotubes (SWNTs) via chemical reduction of the precursor (Pd(2+)). The electrocatalyst showed good electrocatalytic activity toward the oxidation of glucose in the neutral phosphate buffer solution (PBS, pH 7.4) even in the presence of a high concentration of chloride ions. A nonenzymatic amperometric glucose sensor was developed with the use of the Pd-SWNT nanostructure as an electrocatalyst. The sensor had good electrocatalytic activity toward oxidation of glucose and exhibited a rapid response (ca.3 s), a low detection limit (0.2 +/- 0.05 microM), a wide and useful linear range (0.5-17 mM), and high sensitivity (approximately 160 microA mM(-1) cm(-2)) as well as good stability and repeatability. In addition, the common interfering species, such as ascorbic acid, uric acid, 4-acetamidophenol, 3,4-dihydroxyphenylacetic acid, and so forth did not cause any interference due to the use of a low detection potential (-0.35 V vs SCE). The sensor can also be used for quantification of the concentration of glucose in real clinical samples. Therefore, this work has demonstrated a simple and effective sensing platform for nonenzymatic detection of glucose.
A glutamate biosensor based on the electrocatalytic oxidation of reduced nicotinamide adenine dinucleotide (NADH), which was generated by the enzymatic reaction, was developed via employing a single-walled carbon nanotubes/thionine (Th-SWNTs) nanocomposite as a mediator and an enzyme immobilization matrix. The biosensor, which was fabricated by immobilizing glutamate dehydrogenase (GlDH) on the surface of Th-SWNTs, exhibited a rapid response (ca. 5s), a low detection limit (0.1 microM), a wide and useful linear range (0.5-400 microM), high sensitivity (137.3+/-15.7) microA mM(-1)cm(-2), higher biological affinity, as well as good stability and repeatability. In addition, the common interfering species, such as ascorbic acid, uric acid, and 4-acetamidophenol, did not cause any interference due to the use of a low operating potential (190 mV vs. NHE). The biosensor can be used to quantify the concentration of glutamate in the physiological level. The Th-SWNTs system represents a simple and effective approach to the integration of dehydrogenase and electrodes, which can provide analytical access to a large group of enzymes for wide range of bioelectrochemical applications including biosensors and biofuel cells.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.