Healthy subjects and glaucoma patients differ significantly in terms of mean overall corneal thickness and thicknesses of the corneal zones I to VI defined here. The variables mean corneal thickness and mean thicknesses of zones IV and VI are able to discriminate between subjects with or without glaucoma.
Purpose: To compare central corneal thickness (CCT) values obtained by Lenstar (LE), Pentacam (PC), specular microscopy (SM) and ultrasound pachymetry (UP) in healthy corneas and study their influence on intraocular pressure (IOP) readings determined by Goldmann applanation tonometry (GAT). Methods: CCT was measured in 76 healthy subjects by LE, PC, SM and UP. We established Lin's concordance correlation coefficient (ρ-C) between different techniques. The influence of CCT on GAT was established through univariate linear regression models, IOP being the dependent variable. Results: The highest ρ-C was found between LE and SM at 0.94 (95% CI: 0.91-0.96) and between LE and UP at 0.95 (95% CI: 0.94-0.97). IOP readings showed less variability when CCT was determined using LE (7.7%, B = 0.16; 95% CI: 0.004-0.28). Conclusions: Although CCT values obtained with UP, PC, SM and LE show good correlation, these methods are not completely interchangeable. The amount of IOP variation differs when CCT is determined using LE or SM.
.
Purpose: To characterize five models of corneal thickness circular zoning in a sample of healthy controls and a sample of patients with primary open‐angle glaucoma (POAG) and to determine their effect on Goldmann (GAT), dynamic contour (DCT) and rebound tonometers (RT).
Methods: The study participants were 122 controls and 129 cases. Five corneal thickness zoning models (A, B, C, D and E) were constructed. The partitioning pattern consisted of a circle centred at the corneal apex and several concentric rings, until the limbus; the contours of each ring followed the geometry of the corneal contour of each participant. In Model A, the central circle was 1 mm in diameter and five concentric rings were established. Mean was obtained for each zone for both samples and compared between them using a t‐test. The effect on the tonometers of central cornel thickness (CCT) and mean thickness of the zones generated was determined through several linear regression models (one per tonometer and per sample).
Results: According to a t‐test, cases and controls differ in zones I [mean difference (MD): 17.93 μm], V (MD: 25.52 μm) and VI (MD: 31.78 μm) of model A (higher values in the cases sample). RT was affected by CCT (controls: B = 0.089; cases: B = 0.081). DCT was affected by zone IV of model A (controls: B = −0.029; cases: B = −0.012). GAT was affected by CCT (controls: B = 0.043; cases: B = 0.025) and zone III of model A (controls: B = −0.045; cases: B = −0.033).
Conclusion: Our results highlight the importance of the thickness of other regions of the cornea different from its main centre in discriminating between healthy controls and patients with POAG and in IOP measurements made using DCT, GAT and RT.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.