Stable ultrashort light pulses and frequency combs generated by mode-locked lasers have many important applications including high-resolution spectroscopy, fast chemical detection and identification, studies of ultrafast processes, and laser metrology. While compact mode-locked lasers emitting in the visible and near infrared range have revolutionized photonic technologies, the systems operating in the mid-infrared range where most gases have their strong absorption lines, are bulky and expensive and rely on nonlinear frequency down-conversion. Quantum cascade lasers are the most powerful and versatile compact light sources in the mid-infrared range, yet achieving their mode-locked operation remains a challenge, despite dedicated effort. Here we report the demonstration of active mode locking of an external-cavity quantum cascade laser. The laser operates in the mode-locked regime at room temperature and over the full dynamic range of injection currents.
A number of cases of respiratory sensitization to soluble platinum have arisen in the U.K. over the last few years, despite measured 8 h TWA exposure levels below the current long-term exposure limit in most cases. One possible cause of sensitization may be as a result of high exposures over short periods. Short-term sampling has been hampered by inadequate sampling and analysis techniques. This investigation has used two types of personal inhalable sampler, with ICPMS analysis, to take 15 min TWA soluble platinum exposure measurements at three sites. The lower detection limit for soluble platinum salts was approximately 0.01 microgram m-3 for 15 min samples, allowing exposures two orders of magnitude below the exposure limit to be measured. It was found that the majority of short-term exposure levels were significantly below 0.006 mg m-3. No evidence was found for altered work practices during sampling, indicating that either sensitization is occurring at airborne exposure levels below the exposure limit, or there is an alternate route of exposure.
ObjectivesThe United States National Institute for Occupational Safety and Health (NIOSH) is developing a protocol to assess the containment performance of closed system transfer devices (CSTDs) when used for drug preparation (task 1) and administration (task 2) and published a draft protocol in September 2016. Nine possible surrogates were proposed by NIOSH for use in the testing. The objectives of this study were to: (A) select the most appropriate surrogate; (B) validate the NIOSH protocol using this surrogate; and (C) determine the containment performance of four commercial CSTDs as compared with an open system of needle and syringe using the validated NIOSH protocol.Methods2-Phenoxyethanol (2-POE) was selected as a surrogate based on its water solubility, Henry’s volatility constant, detectability by mass spectrometry, and non-toxicity. Standard analytical validation methods including system suitability, limit of detection (LOD), and limit of quantitation (LOQ) as well as system cleaning validation were performed. The amount of 2-POE released when the CSTDs were manipulated according to two tasks defined by NIOSH was determined using mass spectrometry coupled to thermal desorption and gas chromatography. This approach allows sensitivity of detection below 1 part per billion (ppb). Equashield, Tevadaptor (OnGuard), PhaSeal, and ChemoClave were assessed according to manufacturers’ instructions for use.Results2-POE was tested and validated for suitability of use within the NIOSH protocol. A simple and efficient cleaning protocol achieved consistently low background values, with an average value, based on 85 measurements, of 0.12 ppb with a 95% confidence interval (CI) of ±0.16 ppb. This gives an LOD for the tests of 0.35 ppb and an LOQ of 0.88 ppb. The Equashield, Tevadaptor (OnGuard), and PhaSeal devices all showed average releases, based on 10 measurements from five tests, that were less than the LOQ (i.e. < 0.88 ppb), while the ChemoClave Vial Shield with Spinning Spiros showed average releases of 2.9±2.3 ppb and 7.5±17.9 ppb for NIOSH tasks 1 and 2 respectively at the 95% confidence level. The open system of needle and syringe showed releases, based on two measurements from a single test, of 4.2±2.2 ppb and 5.1±1.7 ppb for NIOSH tasks 1 and 2 respectively at the 95% confidence level.Conclusions2-POE proved to be an ideal surrogate for testing of CSTDs using the NIOSH protocol. We propose that a CSTD can be qualified using the NIOSH testing approach if the experimental LOQ is less than 1 ppb and the release values are below the LOQ. Equashield, Tevadaptor (OnGuard), and PhaSeal meet these acceptance criteria and can therefore all be qualified as CSTDs, but the ChemoClave system does not and so would not qualify as a CSTD.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.