Background and Aims: Continuous glucose monitoring (CGM) devices could be useful for real-time management of diabetes therapy. In particular, CGM information could be used in real-time to predict future glucose levels in order to prevent hypo/hyperglycemic events. This paper proposes a new on-line method for predicting future glucose concentration levels from CGM data. Methods:The predictor is implemented with an artificial neural network model (NNM). The inputs of the NNM are the values provided by the CGM sensor during the preceding 20 minutes, while the output is the prediction of glucose concentration at the chosen prediction horizon (PH) time. The method performance is assessed using datasets from two different CGM systems (9 subjects using the Medtronic Guardian and 6 subjects using the Abbott Navigator). Three different PH are used, i.e. 15, 30 and 45 minutes. The NNM accuracy has been estimated by using the root mean square error (RMSE) and prediction delay. Results:The RMSE is around 10, 18 and 27 mg/dl for 15, 30 and 45 minutes of PH, respectively. The prediction delay is around 4, 9 and 14 minutes for upward trends and 5, 15 and 26 minutes for downward trends, respectively. A comparison with a previously published technique, based on an autoregressive model (ARM) [1], has been performed. The comparison shows that, the proposed NNM is more accurate than the ARM, with no significant deterioration in the prediction delay. Conclusions:The proposed NNM is a reliable solution for the on-line prediction of future glucose concentrations from CGM data.
Background:The growth of diabetes prevalence is causing an increasing demand in health care services which affects the clinicians' workload as medical resources do not grow at the same rate as the diabetic population. Decision support tools can help clinicians with the inspection of monitoring data, providing a preliminary analysis to ease their interpretation and reduce the evaluation time per patient. This paper presents Sinedie, a clinical decision support system designed to manage the treatment of patients with gestational diabetes. Sinedie aims to improve access to specialized healthcare assistance, to prevent patients from unnecessary displacements, to reduce the evaluation time per patient and to avoid gestational diabetes adverse outcomes. Methods: A web-based telemedicine platform was designed to remotely evaluate patients allowing them to upload their glycaemia data at home directly from their glucose meter, as well as report other monitoring variables like ketonuria and compliance to dietary treatment. Glycaemia values, not tagged by patients, are automatically labelled with their associated meal by a classifier based on the Expectation Maximization clustering algorithm and a C4.5 decision tree learning algorithm. Two finite automata are combined to determine the patient's metabolic condition, which is analysed by a rule-based knowledge base to generate therapy adjustment recommendations. Diet recommendations are automatically prescribed and notified to the patients, whereas recommendations about insulin requirements are notified also to the physicians, who will decide if insulin needs to be prescribed. The system provides clinicians with a view where patients are prioritized according to their metabolic condition. A randomized controlled clinical trial was designed to evaluate the effectiveness and safety oí Sinedie interventions versus standard care and its impact in the professionals' workload in terms of the clinician's time required per patient; number of face-to-face visits; frequency and duration of telematics reviews; patients' compliance to self-monitoring; and patients' satisfaction. Results: Sinedie was clinically evaluated at "Pare Tauli University Hospital" in Spain during 17 months with the participation of 90 patients with gestational diabetes. Sinedie detected all situations that required a therapy adjustment and all the generated recommendations were safe. The time devoted by clinicians to patients' evaluation was reduced by 27.389% and face-to-face visits per patient were reduced by 88.556%. Patients reported to be highly satisfied with the system, considering it useful and trusting in being well controlled. There was no monitoring loss and, in average, patients measured their glycaemia 3.890 times per day and sent their monitoring data every 3.477 days. Conclusions: Sinedie generates safe advice about therapy adjustments, reduces the clinicians' workload and helps physicians to identify which patients need a more urgent or more exhaustive examination and those who present g...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.