The European Medicines Agency (EMA) regards the potential risks of human medicinal products to the environment and their impacts are assessed, as well as management to limit this impact. Hazard assessment of novel materials, which differ from conventional chemicals, e.g. nanobiomaterials, poses testing challenges and represents a work-in-progress with much focus on the optimization of required methodologies. For this work-in-progress, we here highlight where changes/updates are required in relation to the main elements for international testing based on OECD guidelines, supported by knowledge from the nanotoxicity area. The outline describes two major sections, nanobiomaterials and environmental hazards, including its challenges and learned lessons, with recommendations for implementation in OECD guidelines. Finally, the way forward via a testing strategy is described.
A detailed analytical study on trichlorfon residues in selected vegetables samples has been carried out, focused on the reliable quantification and confirmation of this compound, and on stability of residues under storage. As a consequence, a rapid and sensitive LC-ESI-MS/MS method has been developed for the determination of residues of this insecticide in kaki fruit (flesh and peel) and cauliflower samples. Extraction was performed with acetonitrile using a high-speed blender. After 4-fold dilution of the extract with water, 20 microL was directly injected in the LC-ESI-MS/MS system (triple quadrupole), using matrix-matched standards calibration for quantification. Under optimized MS/MS conditions, limit of detections between 0.006 and 0.013 mg/kg were reached, and a limit of quantification of 0.05 mg/kg was established, with a runtime of only 15 min. Recoveries from spiked blank samples at 0.05 and 0.5 mg/kg were in the range 83-101% with relative standard deviations lower than 10%. The method was applied to treated and untreated samples collected from field residues trials, using quality control samples analysis for the evaluation of the method. Despite the acquisition of two MS/MS transitions in selected reaction monitoring mode, the analysis of treated samples revealed the presence of a chromatographic peak close to the analyte that corresponded to a trichlorfon isobaric compound that shared the same MS/MS transitions. This unusual situation in LC-MS/MS-based procedures required the application of an efficient chromatographic separation to avoid this interference. All experiments have been made in compliance with the principles of Good Laboratory Practices (GLP) and following the European SANCO guidelines for pesticides residue analysis (PRA).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.