Microelectromechanical-systems-based vertical-cavity surface-emitting lasers (MEMS-VCSELs) capable of a 150 nm continuous tuning range near 1310 nm are demonstrated. These devices employ a thin optically pumped active region structure with large free-spectral range, which promotes wide and continuous tuning. To achieve VCSEL emission at 1310 nm, a wide-gain-bandwidth indium phosphide-based multiple quantum well active region is combined with a wide-bandwidth fully oxidised GaAs-based mirror through wafer bonding, with tuning enabled by a suspended dielectric top mirror. These devices are capable of being scanned over the entire tuning range at frequencies up to 500 kHz, making them ideal for applications such as swept source optical coherence tomography and high-speed transient spectroscopy.
Demonstrated are 1060 nm microelectromechanical-systems-based tunable vertical-cavity surfaceemitting lasers (MEMS-VCSELs) with a 100 nm continuous tuning range under repetitively scanned operation at rates beyond 500 kHz and a 90 nm continuous tuning range under static operation. These devices employ a thin strained InGaAs multiple quantum well active region integrated with a fully oxidised GaAs/Al x O y bottom mirror and a suspended dielectric top mirror. The devices are optically pumped via 850 nm light. These ultra-widely tunable lasers represent the first MEMS-VCSELs reported in this wavelength range, and are ideally suited for application in ophthalmic swept-source optical coherence tomography.
In this paper, we present a 1050 nm electrically-pumped micro-electro-mechanically-tunable vertical-cavity-surface-emitting-laser (MEMS-VCSEL) with a record dynamic tuning bandwidth of 63.8 nm, suitable for swept source optical coherence tomography (SS-OCT) imaging. These devices provide reduced cost & complexity relative to previously demonstrated optically pumped devices by obviating the need for a pump laser and associated hardware. We demonstrate ophthalmic SS-OCT imaging with the electrically-pumped MEMS-VCSEL at a 400 kHz axial scan rate for wide field imaging of the in vivo human retina over a 12 mm × 12 mm field and for OCT angiography of the macula over 6 mm × 6 mm & 3 mm × 3 mm fields to show retinal vasculature and capillary structure near the fovea. These results demonstrate the feasibility of electrically pumped MEMS-VCSELs in ophthalmic instrumentation, the largest clinical application of OCT. In addition, we estimate that the 3 dB coherence length in air is 225 meters ± 51 meters, far greater than required for ophthalmic SS-OCT and suggestive of other distance ranging applications.
Since the first demonstration of swept source optical coherence tomography (SS-OCT) imaging using widely tunable micro-electromechanical systems vertical cavity surface-emitting lasers (MEMS-VCSELs) in 2011, VCSEL-based SS-OCT has advanced in both device and system performance. These advances include extension of MEMS-VCSEL center wavelength to both 1060nm and 1300nm, improved tuning range and tuning speed, new SS-OCT imaging modes, and demonstration of the first electrically pumped devices. Optically pumped devices have demonstrated continuous singlemode tuning range of 150nm at 1300nm and 122nm at 1060nm, representing a fractional tuning range of 11.5%, which is nearly a factor of 3 greater than the best reported MEMS-VCSEL tuning ranges prior to 2011. These tuning ranges have also been achieved with wavelength modulation rates of >500kHz, enabling >1 MHz axial scan rates. In addition, recent electrically pumped devices have exhibited 48.5nm continuous tuning range around 1060nm with 890kHz axial scan rate, representing a factor of two increase in tuning over previously reported electrically pumped MEMS-VCSELs in this wavelength range. New imaging modes enabled by optically pumped devices at 1060nm and 1300nm include full eye length imaging, pulsatile Doppler blood flow imaging, high-speed endoscopic imaging, and hand-held wide-field retinal imaging.
No abstract
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.