This work targets mainly the quality control of electronic cigarette liquids. It relies on an analytical control of a “32-product” sample made of several types of e-cigarette liquids taken from various supermarkets and tobacconist’s offices in Morocco. All along this study, we made sure to check both the conformity of the nicotine level indicated in the packaging of each product and the existence of any other components inside the product, especially toxic or unknown impurities. The method used for this study is known under the name of high-performance liquid chromatography. For statistical analysis, we used Student’s t-test for a single sample in order to analyze the relative differences between nicotine quantity reported in the product and the one measured during our experiment. Finally, we used linear regression test to determine the relationship between the nicotine level accuracy on the packaging and the level of toxic impurities in the products. The differences between the nicotine concentrations reported in the packages and the measured ones varied from −100% to +3.3%. The study showed that 31% of analyzed products have an accurate indication of the level of nicotine on the packaging. However, 47% of the studied products showed more than 20% difference between measure and packaging indication. In all analyzed samples, the level of impurities altered from 0 to 32.6%. Furthermore, the level of the nicotine breakdown products did not exceed 2% of the nicotine content in pretty much all of the samples. The actual nicotine content of electronic cigarette refill liquids is not always as precise as what is stated on the packaging; in addition to the level of impurities detected in several brands and that exceeds the European Pharmacopoeia standards, some may even present a risk of causing toxicological damage.
Introduction The preparation of anticancer chemotherapy in a hospital must meet several objectives; the first main is the quality, which can be provided by setting up a surveillance system and a quality control of each preparations. The aim of this work is to present a simple, fast and accurate spectrophotometric method for the routine control of cytotoxic preparations. Materials and methods This is a study carried out in the cytotoxic preparation unit of the university center of Rabat-Sale children’s hospital in Morocco. All samples of preparations were collected and analyzed daily on the site. After validation of the analytical method with respect to many parameters such as: linearity, accuracy and precision according to ICH Q2 guidelines, samples of cytotoxic preparations collected were assayed. Results The results are satisfactory with good level of exactitude, and high precision. Conclusion Compared to other techniques, this method can be considered as a useful alternative in the routine quality control of preparations. It can quickly obtain qualitative and quantitative information with instrumentation and inexpensive reagents.
Preservatives are used in a wide field of application to maintain the quality of products. They are used to deal with the chemical, physical and microbiological problems and the constraints of the development of several formulations. In this work, we tested the stability of antimicrobial preservatives which are the parabens under different stress degradation conditions to evaluate their degree of effectiveness. The tested parabens were incubated in different solutions at different pH, Temperatures, light conditions, and presence or absence of sucrose in solution (create a medium similar of syrups). The HPLC was used for the assay, by a validated method for the parabens assay and the statistical analysis of the data is carried out by JMP software. The results show a direct influence of temperature and pH on the level of parabens, while the influence of light remains negligible. The increase in temperature gives a degree of immunity of parabens levels, especially with the extreme values of pH. This study is one of the first studies of forced decomposition of parabens carried out under the various conditions suggested. The results give an idea of the stability profile of the tested parabens and suggest a model of the conditions of conservation and use of these products in different domains and under different conditions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.