Background:There are > 7,000 e-cigarette flavors currently marketed. Flavoring chemicals gained notoriety in the early 2000s when inhalation exposure of the flavoring chemical diacetyl was found to be associated with a disease that became known as “popcorn lung.” There has been limited research on flavoring chemicals in e-cigarettes.Objective:We aimed to determine if the flavoring chemical diacetyl and two other high-priority flavoring chemicals, 2,3-pentanedione and acetoin, are present in a convenience sample of flavored e-cigarettes.Methods:We selected 51 types of flavored e-cigarettes sold by leading e-cigarette brands and flavors we deemed were appealing to youth. E-cigarette contents were fully discharged and the air stream was captured and analyzed for total mass of diacetyl, 2,3-pentanedione, and acetoin, according to OSHA method 1012.Results:At least one flavoring chemical was detected in 47 of 51 unique flavors tested. Diacetyl was detected above the laboratory limit of detection in 39 of the 51 flavors tested, ranging from below the limit of quantification to 239 μg/e-cigarette. 2,3-Pentanedione and acetoin were detected in 23 and 46 of the 51 flavors tested at concentrations up to 64 and 529 μg/e-cigarette, respectively.Conclusion:Because of the associations between diacetyl and bronchiolitis obliterans and other severe respiratory diseases observed in workers, urgent action is recommended to further evaluate this potentially widespread exposure via flavored e-cigarettes.Citation:Allen JG, Flanigan SS, LeBlanc M, Vallarino J, MacNaughton P, Stewart JH, Christiani DC. 2016. Flavoring chemicals in e-cigarettes: diacetyl, 2,3-pentanedione, and acetoin in a sample of 51 products, including fruit-, candy-, and cocktail-flavored e-cigarettes. Environ Health Perspect 124:733–739; http://dx.doi.org/10.1289/ehp.1510185
BackgroundOccupational exposures to ultrafine particles in the plume generated during laser hair removal procedures, the most commonly performed light based cosmetic procedure, have not been thoroughly characterized. Acute and chronic exposures to ambient ultrafine particles have been associated with a number of negative respiratory and cardiovascular health effects. Thus, the aim of this study was to measure airborne concentrations of particles in a diameter size range of 10 nm to 1 μm in procedure rooms during laser hair removal procedures.MethodsTSI Model 3007 Condensation Particle Counters were used to quantify the particle count concentrations in the waiting and procedure rooms of a dermatology office. Particle concentrations were sampled before, during, and after laser hair removal procedures, and characteristics of each procedure were noted by the performing dermatologist.ResultsTwelve procedures were sampled over 4 days. Mean ultrafine particle concentrations in the waiting and procedure rooms were 14,957.4 particles/cm3 and 22,916.8 particles/cm3 (p < 0.0001), respectively. Compared to background ultrafine particle concentrations before the procedure, the mean concentration in the procedure room was 2.89 times greater during the procedure (p = 0.009) and 2.09 times greater after the procedure (p = 0.007). Duration of procedure (p = 0.006), body part (p = 0.013), and the use of pre-laser lotion/type of laser (p = 0.039), were the most important predictors of ultrafine particle concentrations. Use of a smoke evacuator (a recommended form of local exhaust ventilation) positioned at 30.5 cm from the source, as opposed to the recommended 1–2 in., lowered particle concentrations, but was not a statistically significant predictor (p = 0.49).ConclusionsLaser hair removal procedures can generate high exposures to ultrafine particles for dermatologists and other individuals performing laser hair removal, with exposure varying based on multiple determinants.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.