A signal-to-noise ratio (SNR) analysis is presented for optical coherence tomography (OCT) signals in which time-domain performance is compared with that of the spectral domain. A significant SNR gain of several hundredfold is found for acquisition in the spectral domain. The SNR benefit is demonstrated experimentally in a hybrid time-domain-spectral-domain OCT system.
Abstract:An ultra-high-speed spectral-domain optical coherence tomography system (SD-OCT) was developed for imaging the human retina and optic nerve in vivo at a sustained depth profile (A-line) acquisition speed of 29 kHz. The axial resolution was 6 µ m in tissue and the system had shot-noise-limited performance with a maximum sensitivity of 98.4 dB. 3-dimensional data sets were collected in 11 and 13 seconds for the macula and optic nerve head respectively and are presented to demonstrate the potential clinical applications of SD-OCT in ophthalmology. Additionally, a 3-D volume of the optic nerve head was constructed from the acquired data and the retinal vascular network was visualized.
An ultra-high-speed spectral domain optical Doppler tomography (SD-ODT) system is used to acquire images of blood flow in a human retina in vivo, at 29,000 depth profiles (A-lines) per second and with data acquisition over 99% of the measurement time. The phase stability of the system is examined and image processing algorithms are presented that allow accurate determination of bi-directional Doppler shifts. Movies are presented of human retinal flow acquired at 29 frames per second with 1000 A-lines per frame over a time period of 3.28 seconds, showing accurate determination of vessel boundaries and time-dependent bi-directional flow dynamics in artery-vein pairs. The ultra-high-speed SD-ODT system allows visualization of the pulsatile nature of retinal blood flow, detects blood flow within the choroid and retinal capillaries, and provides information on the cardiac cycle. In summary, accurate video rate imaging of retinal blood flow dynamics is demonstrated at ocular exposure levels below 600 µW.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.