ÃÃIn this study, the authors considered the effect of soil moisture in the emanation process of radon and thoron gases. Weathered granite soil was selected as the test soil and it was packed in a polypropylene container (275 Â 210 mm 2 and 100 mm in height), up to 50 mm in depth from the bottom. The container was covered with the exhalation rate measuring instrument adopting the accumulation method and -particles were counted at 30 s intervals for 30 min to estimate the exhalation rates. A sporadic increase in the radon and thoron exhalation rates was caused by the increase in the moisture content up to 8%. However, the exhalation rates showed a decreasing tendency with the increase in moisture content over 8%. Although the measured radon exhalation rate was about 25% of the calculated one, both measured and calculated radon exhalation rates had similar trends with an increase in the moisture content in the soil. The measured thoron exhalation rate agreed well with the calculated one. When the moisture content was in the range of 3.5-18%, it was considered that applying the correlation between the moisture content and the measured thoron exhalation rate is useful for estimating the thoron effective diffusion coefficient.
ÃÃIn this study, the authors considered the effect of soil moisture in the emanation process of radon and thoron gases. Weathered granite soil was selected as the test soil and it was packed in a polypropylene container (275 Â 210 mm 2 and 100 mm in height), up to 50 mm in depth from the bottom. The container was covered with the exhalation rate measuring instrument adopting the accumulation method and -particles were counted at 30 s intervals for 30 min to estimate the exhalation rates. A sporadic increase in the radon and thoron exhalation rates was caused by the increase in the moisture content up to 8%. However, the exhalation rates showed a decreasing tendency with the increase in moisture content over 8%. Although the measured radon exhalation rate was about 25% of the calculated one, both measured and calculated radon exhalation rates had similar trends with an increase in the moisture content in the soil. The measured thoron exhalation rate agreed well with the calculated one. When the moisture content was in the range of 3.5-18%, it was considered that applying the correlation between the moisture content and the measured thoron exhalation rate is useful for estimating the thoron effective diffusion coefficient.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.