Stretchable optoelectronic circuits, incorporating chip-level LEDs and photodiodes in a silicone membrane, are demonstrated. Due to its highly miniaturized design and tissue-like mechanical properties, such an optical circuit can be conformally applied to the epidermis and be used for measurement of photoplethysmograms. This level of optical functionality in a stretchable substrate is potentially of great interest for personal health monitoring.
Blood oxygen saturation is one of the most prominent measurement parameters in daily clinical routine. However up to now, it is not possible to continuously monitor this parameter reliably in mobile patients. High-risk patients suffering from cardiovascular diseases could benefit from long-term monitoring of blood oxygen saturation. In this paper, we present a minimally invasive, implantable patient monitor which is capable of monitoring vital signs. The capability of this multimodal sensor to subcutaneously determine blood pressure, pulse and ECG has been demonstrated earlier. This paper focuses on monitoring of blood oxygen saturation. Even though the signal amplitudes are much weaker than for standard extracorporeal measurements, photoplethysmographic signals were recorded with high quality in vivo directly on subcutaneous muscle tissue. For the first time, it has been shown that blood oxygen saturation can be measured with an implantable, but extravascular sensor. The sensor was implanted for two weeks in a sheep and did not cause any complications. This opens new perspectives for home monitoring of patients with cardiovascular diseases.
We introduce a minimally invasive, implantable system that uses pulse transit time to determine blood pressure. In contrast to previous approaches, the pulse wave is detected by a photoplethysmographic (PPG) signal, acquired with high quality directly on subcutaneous muscle tissue. Electrocardiograms (ECG) were measured with flexible, implantable electrodes on the same tissue. PPG detection is realized by a flat 20 mm x 6 mm optoelectronic pulse oximeter working in reflection mode. The optical sensor as well as the ECG electrodes can be implanted using minimally invasive techniques, with only a small incision into the skin, making long-term monitoring of blood pressure in day-to-day life for high-risk patients possible. The in vivo measurements presented here show that the deviation to intra-arterial reference measurements of the systolic blood pressure in a physiologically relevant range is only 5.5 mmHg, demonstrated for more than 12 000 pulses. This makes the presented sensor a grade B blood pressure monitor.
A refined model for the photon energy distribution in a living artery is established by solving the radiative transfer equation in a cylindrical geometry, using the Monte Carlo method. Combining this model with the most recent experimental values for the optical properties of flowing blood and the biomechanics of a blood-filled artery subject to a pulsatile pressure, we find that the optical intensity transmitted through large arteries decreases linearly with increasing arterial distension. This finding provides a solid theoretical foundation for measuring photoplethysmograms.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.