Background If the bony region indicating the ilioischial line is established on the preoperative axial computed tomography (CT) image, the distance between the simulated cup and the ilioischial line can be measured on this image so that the surgeon can use these data to define a more accurate preoperative two-dimensional (2D) template of total hip arthroplasty (THA). This study aimed to verify the hypothesis that on the CT axial image, the cortical bone area, indicated by the superimposition of a line (line α) with a perspective projection angle to the ilioischial line on radiography and tangent to the medial acetabular wall, is the cortical bone that represents the ilioischial line on radiography. Methods Study 1: If the two measured distances (distance A’ and distance B) are sufficiently equal, then the hypothesis can be supported. Distance A’ was calculated by multiplying the distance A, between the ilioischial line and the medial margin of the metal cup after THA measured at the level of the hip joint center on the pelvic radiograph, by 0.91 to correct for radiographic magnification. Distance B was defined as the distance between the medial margin of the metal cup and line α on the axial CT image at the level of the hip joint center. These two distances were measured for all 51 hip joints included in the study. Study 2: The difference between distance A and distance A# (distance A on the 2D template) was compared between the group containing 59 primary THAs in which distance B′ was measured (distance B in the simulation) and the control group containing 59 primary THAs. Results Study 1: The average distance for A’ was 4.5 ± 2 mm, and the average distance for B was 4.7 ± 2.1 mm. The difference between distances A and B was 0.2 ± 0.2 mm. Study 2: The mean difference between distance A and distance A# for the measurement and control groups was 1.8 ± 1.3 mm and 3.7 ± 2.4 mm, respectively (P < 0.001). Conclusions The ilioischial line is located in the bony region where line α intersects the medial acetabular wall with a maximum overlap on axial CT images.
Purpose Stability in the sagittal plane, particularly regarding anterior cruciate ligament compensation, and postoperative functionality and satisfaction remain issues in total knee arthroplasty. Therefore, this prospective study compared the clinical outcomes between medial-pivot-based and posterior-stabilised total knee arthroplasty based on anterior translation and clinical scores. Methods To assess outcomes of total knee arthroplasty for varus osteoarthritis, the anterior translation distance of the tibia relative to the femur was measured at 30 and 60° of flexion using a KS measure Arthrometer at 6 months postoperatively. The 2011 Knee Society Score, Forgotten Joint Score, visual analogue scale for pain, and range of motion were assessed at 6 months and 1 year postoperatively. The correlations among each score, anterior translation distance, range of motion, and visual analogue scale score for pain were investigated. Results The medial-pivot and posterior-stabilised groups comprised 70 and 51 patients, respectively. The medial-pivot group exhibited a significantly shorter anterior translation distance at 60° flexion than the posterior-stabilised group. Furthermore, the medial-pivot group achieved significantly better outcomes regarding the visual analogue scale for pain, 2011 Knee Society Score, and Forgotten Joint Score than the posterior-stabilised group. A significant negative correlation was observed between the anterior translation distance and the function score of the 2011 Knee Society Score, whereas a significant positive correlation was found between the anterior translation distance and flexion angle, and between the extension angle and score of the Forgotten Joint Score or 2011 Knee Society Score. Significant negative correlations were also found between the pain visual analogue scale and both the 2011 Knee Society Score and Forgotten Joint Score. Conclusion In total knee arthroplasty for osteoarthritis, the medial-pivot group displayed a shorter anterior translation distance than the posterior-stabilised group at 6 months postoperatively. The visual analogue scale score for pain was also significantly lower in the medial-pivot group than that in the posterior-stabilised group at both 6 months and 1 year postoperatively. Because a correlation was observed between the anterior translation distance and the function score, medial-pivot-based total knee arthroplasty was considered to significantly improve postoperative function compared to posterior-stabilised total knee arthroplasty.
Myxoinflammatory fibroblastic sarcoma (MIFS) is a rare, painless, and intermediate (rarely metastasizing) fibroblastic tumor, which commonly occurs in the extremities, with an equal sex predilection. This sarcoma is composed of a mixed inflammatory infiltrate along with spindled, epithelioid, and bizarre tumor cells in a background of hyaline and myxoid areas. In spite of such a distinctive morphology, the tumor can be a diagnostic challenge, simulating inflammatory conditions as well as neoplastic nature. For accurate diagnosis, the tumor requires extensive clinical, radiological, and pathological investigations. We present a case of MIFS in a 19-year-old female who presented with a mass in the left ankle. After appropriate excision and postoperative radiation therapy, she is free of disease, including recurrence and metastasis, at 12 years postoperatively.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.