A proteomic-based method has been developed for the detection of chicken meat within mixed meat preparations. The procedure is robust and simple, comprising the extraction of myofibrillar proteins, enrichment of target proteins using OFFGEL isoelectric focusing, in-solution trypsin digestion of myosin light chain 3, and analysis of the generated peptides by liquid chromatography-mass spectrometry/mass spectrometry (LC-MS/MS). Using this approach, it was possible for example to detect 0.5% contaminating chicken in pork meat with high confidence. Quantitative detection of chicken meat was done by using AQUA stable isotope peptides made from the sequence of previously selected species-specific peptide biomarkers. Linearity was observed between the amount of the peptide biomarker and the amount of chicken present in the mixture; further independent replication is required now to validate the method. Apart from its simplicity, this approach has the advantage that it can be used effectively for the detection of both raw and cooked meat. The method is robust, reliable, and sensitive, representing a serious alternative to methods currently in use for these purposes. It is amenable to highly processed foods which can be particularly problematic, as the tertiary protein structure is often affected in processed food precluding immunoassays. In addition, this proteomic analysis will permit the determination of definitive discriminatory sequence, unlike the DNA PCR based methods used presently. The present article also demonstrates the translation of the technology to routine mass spectrometry equipment, making the methodology suitable for public analysts.
A new HPLC procedure based on hydrophilic interaction chromatography (HILIC) has been developed for the simultaneous determination of carnosine, anserine, balenine, creatine, and creatinine in meat. This is the first time that HILIC has been directly applied to the study of meat components, having the advantage of not requiring complex cleanup and/or sample derivatization procedures. The chromatographic separation has been developed using a silica column (4.6 x 150 mm, 3 microm), and the proposed methodology is simple, reliable, and fast (<13 min per sample). The method has been validated in terms of linearity, repeatability, reproducibility, and recovery and represents an interesting alternative to methods currently in use for determining the mentioned compounds and other polar substances. The detection limits are 5.64, 8.23, 3.66, 3.99, and 0.06 microg/mL for carnosine, anserine, balenine, creatine, and creatinine, respectively.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.