Background & objectives:Hepatitis B virus (HBV), human immunodeficiency virus (HIV), hepatitis C virus (HCV) and syphilis infections pose a great threat to blood safety. This study was undertaken to investigate the seroprevalence of serologic markers for transfusion transmitted infections (TTIs) among blood donors at a hospital based blood centre in north India over a period of nine years.Methods:The results of serologic markers for TTIs (HBsAg, anti-HCV, anti-HIV and syphilis) of all blood donations (both voluntary and replacement) at our hospital from January 2005 to December 2013 were screened. Additional analysis was conducted to examine the prevalence trends associated with each of the positive marker.Results:The data of 180,477 donors [173,019 (95.86%) males and 7,458 (4.13%) females] were analyzed. Replacement donations [174,939 (96.93%)] represented the majority whereas, only 5,538 (3.06%) donations were from the voluntary donors. The risk of blood being reactive was three times higher in male donors when compared with the female donors. The risk of blood being reactive for one or more infectious markers was 2.1 times higher in replacement donors when compared with the voluntary donors. Seropositivity of HIV, HBsAg, HBcAb, syphilis showed a significant decreasing trend (P<0.05) while there was an increasing trend in HCV infection which was insignificant.Interpretation & conclusions:This study reflects that the risk of TTIs has been decreased over time with respect to HIV, HBV and syphilis, but the trends for HCV remains almost the same in blood donors. Blood transfusion remains a risk factor for the spread of blood-borne infections. Therefore, improvements are needed to strengthen both safety and availability of blood.
Serum samples collected during 1978-79 from residents of the Chiniot and Changa Manga National Forest (CMF) areas of Punjab Province, Pakistan, had over-all neutralizing (N) antibody positive rates for West Nile (WN) virus of 32.8% (n = 192) and 38.5% (n = 239), respectively. Comparison of the age-specific antibody rates indicated that the pattern of exposure to infection was different in the two areas. Samples from a 1968 serosurvey of residents of the CMF area had an age-specific N antibody profile similar to the 1978 CMF sample, but both the over-all N and haemagglutination-inhibition (HI) antibody positive rates were much higher in the 1968 sample. When tested against antigen prepared from the Pakistan I-746 strain of WN virus, the percentage of sera HI antibody positive and the geometric mean titre of the sera were significantly higher than when tested against the Egypt-101 antigen. One of 124 and 11 of 50 sera from the 1978 and 1968 samples from CMF exhibited detectable HI antibody against dengue-3 virus, respectively, indicating cross-reacting flavivirus antibody was present. None of the positive sera had a higher titre against dengue-3 than against WN virus, but four of the 1968 sera reacted to equal titre against both antigens. During the 1978-79 CMF survey, serum samples from domestic and wild animals were tested for WN virus antibody. Of the 317 wild birds captured, 85 were N-antibody positive. The only frequently bled mammal was the Indian cow, from which 21 of 58 samples were positive for WN antibody.
Background & objectives:India has the second highest HIV population in the world with about 2.5-3.0 million cases. HIV-2 cases among general and blood donor population have also been reported mostly from west and south India. This single centre study was carried out to observe the HIV-1 and HIV-2 prevalence among blood donors from north India.Methods:A total of 2,04,677 people were screened for the presence of HIV infection over the 11 year period (1999 to 2009). Till 2004, a third generation ELISA kit was used. From 2005 till January 2009 all tests were done using the fourth generation ELISA kit which detected the presence of HIV-1 P24 antigen and anti-HIV antibodies. From February 2009 onwards, the kits used were Genscreen ULTRA HIV Ag-Ab Assay.Results:A total of 506 (0.247%) donors were found to be repeat reactive for HIV. Of these, 486 (96%) donors tested using the Western blot were found positive for HIV-1 infection. Twenty (4%) donors showed a negative Western blot result, none of the donors were found reactive for HIV-2 infection.Interpretation & conclusions:The prevalence of HIV was 0.249 per cent among blood donors of north India. No HIV-2 case was found among the studied blood donor population indicating that it is not a threat currently.
The accurate estimation of ABO antibody titers is of the utmost importance in organ transplants involving ABO incompatibility. We aim to compare five different methods of titration and analyze the data. Samples of 48 O group blood donors who donated during the month of December 2015 to January 2016 in our institution were subjected to ABO antibody titration by five different methods: immediate spin (IS) tube titer, antihuman globulin phase tube titer, Coomb's gel card titer, gel card titer after dithiotreitol (DTT) treatment of plasma, and the solid phase red cell adherence method. The mean number of titer serial dilution steps in the different titer estimation methods was compared using the paired t-test and McNemar test. A correlation between the methods was tested using Spearman's rho and kappa statistics. The median antiglobulin (AHG) phase tube titers were found to be the highest anti-A (128) and anti-B (192) titers. Significant differences in the ABO antibody titer readings among the five different methods were noted. Titers were reduced by DTT treatment in nearly 50% samples tested for both anti-A and anti-B titers. Average agreements between the DTT-applied AHG phase gel card titers and the solid phase red cell adherence (SPRCA) titers was observed for anti-A (κ = 0.473) and anti-B (κ = 0.530). The AHG phase tube and gel cards titers showed poor agreements. There are differences in the interpretability of the ABO antibody titer among different techniques. Consistent and uniform application of the method for titration throughout the treatment of a patient is highly essential.
We report a large Stokes shift and broad emission band in a Mn-based organic–inorganic hybrid halide, (guanidinium)6Mn3Br12 [GuMBr], consisting of trimeric units of distorted MnBr6 octahedra representing a zero-dimensional compound with a liquid like crystalline lattice. Analysis of the photoluminescence (PL) line width and Raman spectra reveals the effects of electron–phonon coupling, suggestive of the formation of Frenkel-like bound excitons. These bound excitons, regarded as the self-trapped excitons (STEs), account for the large Stokes shift and broad emission band. The excited-state dynamics was studied using femtosecond transient absorption spectroscopy, which confirms the STE emission. Further, this compound is highly emissive with a PL quantum yield of ∼50%. With chloride ion incorporation, we observe enhancement of the emissive properties and attribute it to the effects of intrinsic quantum confinement. Localized electronic states in flat bands lining the gap and their strong coupling with phonons are confirmed with first-principles calculations.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.