Lactate is a potential energy source for the brain. The aim of this study was to establish whether systemic lactate is a brain energy source. We measured in vivo cerebral lactate kinetics and oxidation rates in 6 healthy individuals at rest with and without 90 mins of intravenous lactate infusion (36 mumol per kg bw per min), and during 30 mins of cycling exercise at 75% of maximal oxygen uptake while the lactate infusion continued to establish arterial lactate concentrations of 0.89+/-0.08, 3.9+/-0.3, and 6.9+/-1.3 mmol/L, respectively. At rest, cerebral lactate utilization changed from a net lactate release of 0.06+/-0.01 to an uptake of 0.16+/-0.07 mmol/min during lactate infusion, with a concomitant decrease in the net glucose uptake. During exercise, the net cerebral lactate uptake was further increased to 0.28+/-0.16 mmol/min. Most (13)C-label from cerebral [1-(13)C]lactate uptake was released as (13)CO(2) with 100%+/-24%, 86%+/-15%, and 87%+/-30% at rest with and without lactate infusion and during exercise, respectively. The contribution of systemic lactate to cerebral energy expenditure was 8%+/-2%, 19%+/-4%, and 27%+/-4% for the respective conditions. In conclusion, systemic lactate is taken up and oxidized by the human brain and is an important substrate for the brain both under basal and hyperlactatemic conditions.
Several techniques assessing cardiac output (Q) during exercise are available. The extent to which the measurements obtained from each respective technique compares to one another, however, is unclear. We quantified Q simultaneously using four methods: the Fick method with blood obtained from the right atrium (Q(Fick-M)), Innocor (inert gas rebreathing; Q(Inn)), Physioflow (impedance cardiography; Q(Phys)), and Nexfin (pulse contour analysis; Q(Pulse)) in 12 male subjects during incremental cycling exercise to exhaustion in normoxia and hypoxia (FiO2 = 12%). While all four methods reported a progressive increase in Q with exercise intensity, the slopes of the Q/oxygen uptake (VO2) relationship differed by up to 50% between methods in both normoxia [4.9 ± 0.3, 3.9 ± 0.2, 6.0 ± 0.4, 4.8 ± 0.2 L/min per L/min (mean ± SE) for Q(Fick-M), Q(Inn), QP hys and Q(Pulse), respectively; P = 0.001] and hypoxia (7.2 ± 0.7, 4.9 ± 0.5, 6.4 ± 0.8 and 5.1 ± 0.4 L/min per L/min; P = 0.04). In hypoxia, the increase in the Q/VO2 slope was not detected by Nexfin. In normoxia, Q increases by 5-6 L/min per L/min increase in VO2, which is within the 95% confidence interval of the Q/VO2 slopes determined by the modified Fick method, Physioflow, and Nexfin apparatus while Innocor provided a lower value, potentially reflecting recirculation of the test gas into the pulmonary circulation. Thus, determination of Q during exercise depends significantly on the applied method.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.