<p>SNSU TK-BSN’s capability in determining the temperature coefficients of a standard resistor has been improved. The temperature coefficient is one of the important parameter in determining the definition of the standard resistor. Currently, the measurement result has been reported together with the measurement uncertainty. The determination itself is based on a numerical approach of Taylor Series Approximation (TSA) instead of based on a fitting to a certain equation. And by this determination, the uncertainty was calculated. The determination was validated by comparing the measurement result committed by SNSU TK-BSN to that of by the manufacturer. The equation for the temperature coefficient follows the parabolic equation with an alpha coefficient of -5.30 x 10-8 Ω/Ω/°C and beta coefficient of -4.70 x 10-8 Ω/Ω/°C<sup>2</sup>, with the respective uncertainties of 2.4 x 10-8 Ω/Ω/°C and 1.6x 10-8 Ω/Ω/°C<sup>2</sup>, respectively. SNSU TK-BSN measurement results in determining the temperature coefficient in agreement with the manufacturer's measurement results show an appropriate value. This correspondence has an equivalent degree of 0.20 for the alpha temperature coefficient and 0.27 for the beta coefficient.</p>
<p>An experimental validation of flatness measurement based on image processing technique has been performed. The purpose of this study is to know the performance of the image processing technique in the flatness measurement. In addition, this technique will be used as development of current measurement technique that is performed manually. The advantage of using this method is that in the future the measurement system will run semi-automatically, so it can increase the capacity. This study is used 3 samples of optical flat with different in diameter (i.e. 25 mm, 45 mm, and 75 mm). The validation has been performed by comparing measurement results of the image processing technique and the manual technique through degree of equivalence evaluation. The error numbers based on the degree of equivalence criteria between the image processing technique and the manual technique for the flatness measurement of 25 mm, 45 mm, and 75 mm are 0.02, 0.09, and 0.11 respectively. According to those error numbers, the image processing technique measurement results is in agreement with the manual technique. Moreover, those results have validated that the image processing technique has good performance and can potentially be implemented to the flatness measurement.</p>
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.