Chan Su, Lu-Shen-Wan, Dan Shen, and Asian ginseng are traditionally used to treat a number of conditions, including cardiovascular disease. All of these traditional Chinese medicines exhibit cardioactive properties. Digoxin is a cardioactive drug with a narrow therapeutic range (0.8-1.9 ng/mL). A patient taking digoxin may also take these Chinese medicines for their cardiotonic effects. Moreover, the active components of these medicines that are responsible for cardiotonic effects bear structural similarities to digoxin. Therefore, we studied the potential interference of these Chinese medicines with two digoxin immunoassays--the Tina-quant (Roche Diagnostics) and the Beckman (Synchron LX system)--and compared the values with the fluorescence polarization immunoassay (FPIA; Abbott Laboratories). When very small amounts (2-5 microL) of aqueous extract of Chan Su or Lu-Shen-Wan were added to drug-free serum, we observed high digoxin-like immunoreactivity with the FPIA. In contrast, when ethyl acetate extract of Dan Shen or microliter amounts of ginseng extract were added to drug-free serum, we observed modest digoxin-like immunoreactivity with the FPIA, but no apparent digoxin activity with the Roche and Beckman digoxin immunoassays. When aliquots of a digoxin pool prepared from patients receiving digoxin were supplemented with these Chinese medicines, we observed the most significant interference with the FPIA. The presence of endogenous digoxin-like immunoreactive substances can have additive effects with these Chinese medicines and falsely increase apparent digoxin levels by the FPIA. On the other hand, the Roche and Beckman assays were free from interference from DLIS but showed significant interference from Chan Su and Lu-Shen-Wan. We conclude that the FPIA showed the most significant interference from all four of the Chinese medicines we studied. However, the Roche and Beckman assays showed no interference from two (Dan Shen and Asian ginseng) of the four Chinese medicines we studied.
Background Significant positive bias of bilirubin in the Trinder salicylate method on automated analysers has been reported. Because the fluorescence polarization immunoassay (FPIA) for salicylate is also widely used in the clinical laboratory, we studied the potential interference of bilirubin in the salicylate FPIA.
We conclude that MPA concentrations determined by the CEDIA assay showed significant positive bias compared to HPLC-UV method. Therefore, caution must be exercised in interpreting therapeutic drug monitoring result of MPA if CEDIA assay is used.
Because of a published report indicating significant interference of hydroxyzine with the particle-enhanced turbidimetric inhibition immunoassay (PENTINA) carbamazepine assay, we investigated whether such interference can be avoided by using the ADVIA Centaur carbamazepine assay. Both the Dimension Vista analyzer and ADVIA Centaur analyzer are available from Siemens Diagnostics. Aliquots of a drug-free serum pool were supplemented with various concentrations of hydroxyzine or cetirizine (0.05 microg/mL to 20 microg/mL covering therapeutic and toxic levels in serum) followed by analysis using both assays. We observed significant apparent carbamazepine concentrations using the PENTINA assay but no apparent carbamazepine level using the ADVIA Centaur assay. Because crossreactivity should be studied in the presence of the primary analyte, we also prepared a serum carbamazepine pool from patients receiving carbamazepine and then supplemented aliquots of this pool with various amounts of hydroxyzine or cetirizine followed by reanalyzing carbamazepine concentration using both assays. We observed falsely elevated carbamazepine values using the PENTINA assay but no interference was observed using the ADVIA Centaur assay. However, the falsely elevated carbamazepine values using the PENTINA assay were clinically significant at hydroxyzine or cetirizine concentrations expected in patients with severe overdoses with these drugs. We conclude that the ADVIA Centaur carbamazepine assay is free from interference of both hydroxyzine and cetirizine.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.