FIG. 3. Reference intervals for 70 protein analytes in plasma.Abundance is plotted on a log scale spanning 12 orders of magnitude. Where only an upper limit is quoted, the lower end of the interval line shows an arrowhead. The classical plasma proteins are clustered to the left (high abundance), the tissue leakage markers (e.g. enzymes and troponins) are clustered in the center, and cytokines are clustered to the right (low abundance). Hemoglobin is included (far left) for comparison. Data were obtained from the Specialty Laboratories publications (154). TPA, tissue plasminogen activator; GCSF, granulocyte colony-stimulating factor; TNF, tumor necrosis factor. Additions & CorrectionsWe suggest that subscribers photocopy these corrections and insert the photocopies at the appropriate places where the article to be corrected originally appeared. Authors are urged to introduce these corrections into any reprints they distribute. Secondary (abstract) services are urged to carry notice of these corrections as prominently as they carried the original abstracts.
The human plasma proteome holds the promise of a revolution in disease diagnosis and therapeutic monitoring provided that major challenges in proteomics and related disciplines can be addressed. Plasma is not only the primary clinical specimen but also represents the largest and deepest version of the human proteome present in any sample: in addition to the classical "plasma proteins," it contains all tissue proteins (as leakage markers) plus very numerous distinct immunoglobulin sequences, and it has an extraordinary dynamic range in that more than 10 orders of magnitude in concentration separate albumin and the rarest proteins now measured clinically. Although the restricted dynamic range of conventional proteomic technology (two-dimensional gels and mass spectrometry) has limited its contribution to the list of 289 proteins (tabulated here) that have been reported in plasma to date, very recent advances in multidimensional survey techniques promise at least double this number in the near future. Abundant scientific evidence, from proteomics and other disciplines, suggests that among these are proteins whose abundances and structures change in ways indicative of many, if not most, human diseases. Nevertheless, only a handful of proteins are currently used in routine clinical diagnosis, and the rate of introduction of new protein tests approved by the United States Food and Drug Administration (FDA) has paradoxically declined over the last decade to less than one new protein diagnostic marker per year. We speculate on the reasons behind this large discrepancy between the expectations arising from proteomics and the realities of clinical diagnostics and suggest approaches by which protein-disease associations may be more effectively translated into diagnostic tools in the future.
Quantitative LC-MS/MS assays were designed for tryptic peptides representing 53 high and medium abundance proteins in human plasma using a multiplexed multiple reaction monitoring (MRM) approach. Of these, 47 produced acceptable quantitative data, demonstrating within-run coefficients of variation (CVs) (n ؍ 10) of 2-22% (78% of assays had CV <10%). A number of peptides gave CVs in the range 2-7% in five experiments (10 replicate runs each) continuously measuring 137 MRMs, demonstrating the precision achievable in complex digests. Depletion of six high abundance proteins by immunosubtraction significantly improved CVs compared with whole plasma, but analytes could be detected in both sample types. Replicate digest and depletion/digest runs yielded correlation coefficients (R Accurate quantitation of proteins and peptides in plasma and serum is a challenging problem because of the complexity and extreme dynamic range that characterize these samples (1). The widely adopted separative (survey) approach to proteomics, in which an attempt is made to detect all components, has proven to be limited in sensitivity toward low abundance proteins (2) and typically provides limited quantitative precision. The alternative candidate-based approach, which relies on specific assays optimized for quantitative detection of selected proteins, can provide significantly increased sensitivity (into the pg/ml range) and precision (CVs 1 Ͻ 5-10%) at the cost of restricting discovery potential toward novel proteins (3). In practice, a combination of these approaches (one or more survey approaches for de novo biomarker discovery coupled with a candidate-based approach to biomarker validation in large sample sets) appears to provide an effective staged pipeline (4) for generation of valid plasma biomarkers of disease, risk, and therapeutic response.Candidate-based specific assays rely on the specificity of capture or detection methods to select a specific molecule as analyte. Capture reagents such as antibodies can provide extreme specificity (particularly when two different antibodies are used as in a sandwich immunoassay) and form the basis of most existing clinical protein assays. There is intense interest in miniaturizing sets of such assays (5, 6) in array formats (on planar substrates, beads, etc.), although significant problems remain in the production of suitable antibodies and in the simultaneous optimization of multiple assays in one fluid volume.Mass spectrometry provides an alternative assay approach, relying on the discriminating power of mass analyzers to select a specific analyte and on ion current measurements for quantitation. In the field of analytical chemistry, many small molecule analytes (e.g. drug metabolites (7), hormones (8), protein degradation products (9), and pesticides (10)) are routinely measured using this approach at high throughput with great precision (CV Ͻ 5%). Most such assays use electrospray ionization followed by two stages of mass selection: a first stage (MS1) selecting the mass of the intact an...
Verification of candidate biomarkers relies upon specific, quantitative assays optimized for selective detection of target proteins, and is increasingly viewed as a critical step in the discovery pipeline that bridges unbiased biomarker discovery to preclinical validation. Although individual laboratories have demonstrated that multiple reaction monitoring (MRM) coupled with isotope dilution mass spectrometry can quantify candidate protein biomarkers in plasma, reproducibility and transferability of these assays between laboratories have not been demonstrated. We describe a multilaboratory study to assess reproducibility, recovery, linear dynamic range and limits of detection and quantification of multiplexed, MRM-based assays, conducted by NCI-CPTAC. Using common materials and standardized protocols, we demonstrate that these assays can be highly reproducible within and across laboratories and instrument platforms, and are sensitive to low µg/ml protein concentrations in unfractionated plasma. We provide data and benchmarks against which individual laboratories can compare their performance and evaluate new technologies for biomarker verification in plasma.Proteomic technologies based on mass spectrometry (MS) have emerged as preferred components of a strategy for discovery of diagnostic, prognostic and therapeutic protein biomarkers. Because of the stochastic sampling of proteomes in unbiased analyses and the associated high false-discovery rate, tens to hundreds of potential biomarkers are often reported in discovery studies. Those few that will ultimately show sufficient sensitivity and specificity for a given medical condition must thus be culled from lengthy lists of candidates -a particularly challenging aspect of the biomarker-development pipeline and currently its main limiting step. In this context, it is highly desirable to verify, by more targeted quantitative methods, the levels of candidate biomarkers in body fluids, cells, tissues or organs from healthy individuals and affected patients in large enough sample numbers to confirm statistically relevant differences 1, 2. Verification of novel biomarkers has relied primarily on the use of sensitive, specific, high-throughput immunoassays, whose development depends critically on the availability of suitable well-characterized antibodies. However, antibody reagents of sufficient specificity and sensitivity to assay novel protein biomarkers in plasma are generally not available. The high cost and long development time required to generate high-quality immunoassay reagents, as well as technical limitations in multiplexing immunoassays for panels of biomarkers, is strong motivation to develop more straightforward quantitative approaches exploiting the sensitivity and molecular specificity of mass spectrometry.Recently, multiple reaction monitoring (MRM) coupled with stable isotope dilution (SID)-MS for direct quantification of proteins in cell lysates as well as human plasma and serum has been shown to have considerable promise 3- RESULTS Study de...
A method (denoted SISCAPA) for quantitation of peptides in complex digests is described. In the method, anti-peptide antibodies immobilized on 100 nanoliter nanoaffinity columns are used to enrich specific peptides along with spiked stable-isotope-labeled internal standards of the same sequence. Upon elution from the anti-peptide antibody supports, electrospray mass spectrometry is used to quantitate the peptides (natural and labeled). In a series of pilot experiments, tryptic test peptides were chosen for four proteins of human plasma (hemopexin, alpha1 antichymotrypsin, interleukin-6, and tumor necrosis factor-alpha) from a pool of 10,203 in silico tryptic peptide candidates representing 237 known plasma components. Rabbit polyclonal antibodies raised against the chosen peptide sequences were affinity purified and covalently immobilized on POROS supports. Binding and elution from these supports was shown to provide an average 120-fold enrichment of the antigen peptide relative to others, as measured by selected ion monitoring (SIM) or selected reaction monitoring (SRM) electrospray mass spectrometry. The columns could be recycled with little loss in binding capacity, and generated peptide ion current measurements with cycle-to-cycle coefficients of variation near 5%. Anti-peptide antibody enrichment will contribute to increased sensitivity of MS-based assays, particularly for lower abundance proteins in plasma, and may ultimately allow substitution of a rapid bind/elute process for the time-consuming reverse phase separation now used as a prelude to online MS peptide assays. The method appears suitable for rapid generation of assays for defined proteins, and should find application in the validation of diagnostic protein panels in large sample sets.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.