Viral infections kill millions of people and new antivirals are needed. Nontoxic drugs that irreversibly inhibit viruses (virucidal) are postulated to be ideal. Unfortunately, all virucidal molecules described to date are cytotoxic. We recently developed nontoxic, broad-spectrum virucidal gold nanoparticles. Here, we develop further the concept and describe cyclodextrins, modified with mercaptoundecane sulfonic acids, to mimic heparan sulfates and to provide the key nontoxic virucidal action. We show that the resulting macromolecules are broad-spectrum, biocompatible, and virucidal at micromolar concentrations in vitro against many viruses [including herpes simplex virus (HSV), respiratory syncytial virus (RSV), dengue virus, and Zika virus]. They are effective ex vivo against both laboratory and clinical strains of RSV and HSV-2 in respiratory and vaginal tissue culture models, respectively. Additionally, they are effective when administrated in mice before intravaginal HSV-2 inoculation. Lastly, they pass a mutation resistance test that the currently available anti-HSV drug (acyclovir) fails.
With the ever-increasing production of electronics, there is an ensuing need for gold extraction from sources other than virgin mines. Currently, there are no technologies reported to date that can effectively and selectively concentrate ultratrace amounts of gold from liquid sources. Here, we provide a blueprint for the design of several highly porous composites made up of a metal−organic framework (MOF) template and redox active, polymeric building blocks. One such composite, Fe-BTC/PpPDA, is shown to rapidly extract trace amounts of gold from several complex water mixtures that include wastewater, fresh water, ocean water, and solutions used to leach gold from electronic waste and sewage sludge ash. The material has an exceptional removal capacity, 934 mg gold/g of composite, and extracts gold from these complex mixtures at recordbreaking rates, in as little as 2 min. Further, due to the high cyclability, we demonstrate that the composite can effectively concentrate gold and yield purities of 23.9 K.
An electrostatic-spray ionization (ESTASI) method has been used for mass spectrometry (MS) analysis of samples deposited in or on an insulating substrate. The ionization is induced by a capacitive coupling between an electrode and the sample. In practice, a metallic electrode is placed close to but not in direct contact with the sample. Upon application of a high voltage pulse to the electrode, an electrostatic charging of the sample occurs leading to a bipolar spray pulse. When the voltage is positive, the bipolar spray pulse consists first of cations and then of anions. This method has been applied to a wide range of geometries to emit ions from samples in a silica capillary, in a disposable pipet tip, in a polymer microchannel, or from samples deposited as droplets on a polymer plate. Fractions from capillary electrophoresis were collected on a polymer plate for ESTASI MS analysis.
The Consortium for Top-Down Proteomics (www.topdownproteomics.org) launched the present study to assess the current state of top-down mass spectrometry (TD MS) and middle-down mass spectrometry (MD MS) for characterizing monoclonal antibody (mAb) primary structures, including their modifications. To meet the needs of the rapidly growing therapeutic antibody market, it is important to develop analytical strategies to characterize the heterogeneity of a therapeutic product's primary structure accurately and reproducibly. The major objective of the present study is to determine whether current TD/MD MS technologies and protocols can add value to the more commonly employed bottom-up (BU) approaches with regard to confirming protein integrity, sequencing variable domains, avoiding artifacts, and revealing modifications and their locations. We also aim to gather information
Pairing light and heavy chains in monoclonal antibodies (mAbs) using top-down (TD) or middle-down (MD) mass spectrometry (MS) may complement the sequence information on single chains provided by highthroughput genomic sequencing and bottom-up proteomics, favoring the rational selection of drug candidates. The 50 kDa F(ab) subunits of mAbs are the smallest structural units that contain the required information on chain pairing. These subunits can be enzymatically produced from whole mAbs and interrogated in their intact form by TD/MD MS approaches. However, the high structural complexity of F(ab) subunits requires increased sensitivity of the modern TD/MD MS for a comprehensive structural analysis. To address this and similar challenges, we developed and applied a multiplexed TD/MD MS workflow based on spectral averaging of tandem mass spectra (MS/MS) across multiple liquid chromatography (LC)−MS/MS runs acquired in reduced or full profile mode using an Orbitrap Fourier transform mass spectrometer (FTMS). We first benchmark the workflow using myoglobin as a reference protein, and then validate it for the analysis of the 50 kDa F(ab) subunit of a therapeutic mAb, trastuzumab. Obtained results confirm the envisioned benefits in terms of increased signal-to-noise ratio of product ions from utilizing multiple LC−MS/MS runs for TD/MD protein analysis using mass spectral averaging. The workflow performance is compared with the earlier introduced multiplexed TD/MD MS workflow based on transient averaging in Orbitrap FTMS. For the latter, we also report on enabling absorption mode FT processing and demonstrate its comparable performance to the enhanced FT (eFT) spectral representation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.