Zephyr EBV provides clinically meaningful benefits in lung function, exercise tolerance, dyspnea, and quality of life out to at least 12 months, with an acceptable safety profile in patients with little or no collateral ventilation in the target lobe. Clinical trial registered with www.clinicaltrials.gov (NCT 01796392).
BACKGROUND: The diagnosis of peripheral pulmonary lesions (PPL) continues to present clinical challenges. Despite extensive experience with guided bronchoscopy, the diagnostic yield has not improved significantly. Robotic-assisted bronchoscopic platforms have been developed potentially to improve the diagnostic yield for PPL. Presently, limited data exist that evaluate the performance of robotic systems in live human subjects. RESEARCH QUESTION: What is the safety and feasibility of robotic-assisted bronchoscopy in patients with PPLs? STUDY DESIGN AND METHODS: This was a prospective, multicenter pilot and feasibility study that used a robotic bronchoscopic system with a mother-daughter configuration in patients with PPL 1 to 5 cm in size. The primary end points were successful lesion localization with the use of radial probe endobronchial ultrasound (R-EBUS) imaging and incidence of procedure related adverse events. Robotic bronchoscopy was performed in patients with the use of direct visualization, electromagnetic navigation, and fluoroscopy. After the use of R-EBUS imaging, transbronchial needle aspiration was performed. Rapid on-site evaluation (ROSE) was used on all cases. Transbronchial needle aspiration alone was sufficient when ROSE was diagnostic; when ROSE was not diagnostic, transbronchial biopsy was performed with the use of the robotic platform, followed by conventional guided bronchoscopic approaches at the discretion of the investigator. RESULTS: Fifty-five patients were enrolled at five centers. One patient withdrew consent, which left 54 patients for data analysis. Median lesion size was 23 mm (interquartile range, 15 to 29 mm). R-EBUS images were available in 53 of 54 cases. Lesion localization was successful in 51 of 53 patients (96.2%). Pneumothorax was reported in two of 54 of the cases (3.7%); tube thoracostomy was required in one of the cases (1.9 %). No additional adverse events occurred. INTERPRETATION: This is the first, prospective, multicenter study of robotic bronchoscopy in patients with PPLs. Successful lesion localization was achieved in 96.2% of cases, with an adverse event rate comparable with conventional bronchoscopic procedures. Additional large prospective studies are warranted to evaluate procedure characteristics, such as diagnostic yield.
Context.— The need for appropriate specimen use for ancillary testing has become more commonplace in the practice of pathology. This, coupled with improvements in technology, often provides less invasive methods of testing, but presents new challenges to appropriate specimen collection and handling of these small specimens, including thoracic small biopsy and cytology samples. Objective.— To develop a clinical practice guideline including recommendations on how to obtain, handle, and process thoracic small biopsy and cytology tissue specimens for diagnostic testing and ancillary studies. Methods.— The College of American Pathologists convened an expert panel to perform a systematic review of the literature and develop recommendations. Core needle biopsy, touch preparation, fine-needle aspiration, and effusion specimens with thoracic diseases including malignancy, granulomatous process/sarcoidosis, and infection (eg, tuberculosis) were deemed within scope. Ancillary studies included immunohistochemistry and immunocytochemistry, fluorescence in situ hybridization, mutational analysis, flow cytometry, cytogenetics, and microbiologic studies routinely performed in the clinical pathology laboratory. The use of rapid on-site evaluation was also covered. Results.— Sixteen guideline statements were developed to assist clinicians and pathologists in collecting and processing thoracic small biopsy and cytology tissue samples. Conclusions.— Based on the systematic review and expert panel consensus, thoracic small specimens can be handled and processed to perform downstream testing (eg, molecular markers, immunohistochemical biomarkers), core needle and fine-needle techniques can provide appropriate cytologic and histologic specimens for ancillary studies, and rapid on-site cytologic evaluation remains helpful in appropriate triage, handling, and processing of specimens.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.