Objective
The aim of this study was to evaluate the meniscal regeneration and arthritic changes after partial meniscectomy and application of either polyurethane scaffold or novel multilayer meniscal scaffold in a rabbit model.
Methods
Sixteen NewZealand rabbits were randomly divided into three groups. A reproducible 1.5-mm cylindrical defect was created in the avascular zone of the anterior horn of the medial meniscus bilaterally. Defects were filled with the polyurethane scaffold in Group 1 (n:6) and with novel multilayer scaffold in Group 2 (n:6). Rabbits in Group 3 (n:4) did not receive any treatment and defects were left empty. All animals were sacrificed after 8 weeks and bilateral knee joints were taken for macroscopic, biomechanical, and histological analysis. After excision of menisci, inked condylar surfaces and tibial plateaus were evaluated for arthritic changes. Digital photographs of excised menisci were also obtained and surface areas were measured by a computer software. Indentation testing of the tibial condyles and compression tests for the relevant meniscal areas was also performed in all groups. Histological analysis was made and all specimens were scored according to Rodeo scoring system.
Results
No signs of inflammation or infection were observed in any animals. A significant difference was observed between meniscus surface areas of the multilayer scaffold group (20.13 ± 1.91 mm
2
) and the group with empty meniscus defects (15.62 ± 2.04 mm
2
) (p = 0.047). The results of biomechanical compression tests revealed a significant difference between the Hayes scores of the second group (1.728) and the empty defect group (0,467) (p = 0.029). Intact meniscal tissue showed higher mechanical properties than all the defected samples. Multilayer scaffold group demonstrated the closest results compared to healthy meniscus tissue. Tibia indentation tests and histological evaluation showed no significant differences between groups (p = 0.401 and p = 0.186 respectively).
Conclusions
In this study, the initial evaluation of novel multilayer meniscal scaffold prevented the shrinkage that may occur in the meniscus area and demonstrated superior biomechanical results compared to empty defects. No adverse events related to scaffold material was observed. Besides, promising biomechanical and histological results, comparable to polyurethane scaffold, were obtained.
Purpose The aim of the present study was to prospectively evaluate the elbow flexion and supination strengths and the functional outcomes of patients following arthroscopic rotator cuff repair combined with simultaneous biceps tenodesis. Methods 19 patients who underwent arthroscopic rotator cuff repair and biceps tenodesis with at least 24 months of follow-up were included. Patients were evaluated using a visual analog scale (VAS) for bicipital groove pain, American Shoulder and Elbow Surgeons (ASES), and constant scores (CS), biceps apex distance (BAD), elbow flexion, and supination strengths. Results The VAS for biceps groove measurement averages in the postoperative 6th, 12th, and 24th months was lower in comparison to preoperative data and was considered to be statistically significant ( p < .05). The constant score, an average of all postoperative measurements and scores, was found to be higher than preoperative values and was considered to be statistically significant ( p < .01). There was a significant difference in the operated and non-operated forearm supination and elbow flexion muscle strength measurements at the postoperative 3- and 6-month follow-ups ( p < .01). Conclusion Arthroscopic biceps tenodesis into the anchors of the lateral row in combination with rotator cuff repair provides an increase in the strength of elbow flexion and forearm supination, while decreasing pain. Level of Evidence Level IV
An 84-year-old male patient with no known comorbidity was admitted to the emergency department with complaints of dyspnea and respiratory distress. The patient was referred to the COVID outpatient clinic, laboratory and radiology tests were performed. Thoracic CT scan of the patient showed large peripheral patchy ground glass densities observed in the lower lobes of both lungs. CT imaging findings were evaluated by an experienced radiologist and reported as COVID-19 pneumonia. The patient, who was self-isolated at home for 5 days, presented to the emergency department again on the fifth day with complaints of respiratory distress, fever, bruising with cough, and loss of peripheral pulse in the left lower extremity. Necessary tests were performed on the patient. An above-knee amputation was performed when a diagnosis of limb ischemic necrosis was made and no revascularization attempt was considered by the CVS department. This case study describes the coexistence of sudden lower extremity thrombosis and Covid-19 in our case without a known chronic disease.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.