0.3847, 0.0891, 0.096 และ0.2829 mm 2 เที ยบกั บ 1.143, 0.246, 0.108 และ 0.269 mm 2 ตามลํ าดั บ เมื ่ อประเมิ นจากกระแส สู งสุ ดสํ าหรั บปลากระป องทั ้ ง 3 ยี ่ ห อและผั กผสมดองเค็ มซี เซ็ กฉ าย) คํ าสํ าคั ญ: แผ นเหล็ กเคลื อบแล็ กเกอร , เทคนิ คโพเทนชิ โอสแตติ ก, กล องจุ ลทรรศน
AbstractLacquer coated steel can is widely used for different types of food e.g. sea-food and fruit. Thus, can factories have to inspect the quality of lacquered can for corrosion resistance on surrounding food. For this purpose electrochemical technique was used to accelerate corrosion process by DC voltage. 6V potential was applied for 10 seconds to lacquered can containing different kinds of solutions i.e., 2%w/w NaCl, 2%w/w NaOH, 2%w/w citric acid and 2%w/w Na 2 S 2 O 5 , respectively. Lacquered can which could not endure the solution at high voltage would corrode. Failure of lacquered can could be analyzed quantitatively from the amount of maximum currents and total amount of charges (current time) released. Current was potentiostatically plotted against time and calibration curve was made from maximum of the dissolution currents and charges of different sites of wires in various solutions. Corrosion currents and charges of dissolved wires were plotted against corroded area on the calibration curve. Lacquered cans from factory were tested and it was found that the currents were in the range of 10-1700 µA. The results showed that these cans were in good conditions and least or no corrosion was found. Food cans were purchased from supermarket and were tested in similar ways. Maximum currents and charges were determined and calculated as corroded areas. When compared the outcome from calibration curve with the result from microscope, it was evidently revealed that corroded areas calculating from optical microscope images were under estimated which were a little bit lower than those calculated from calibration curves of maximum currents and charges [evaluated values from microscope were 0.3847, 0.0891, 0.096 and 0.2829 mm 2 compared with 1.143, 0.246, 0.108 and 0.269 mm 2 , respectively, which were evaluated from maximum current for sardines in tomato sauce (Three brands) and salted mixed vegetables].
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.