Breast thickness is the most important parameter in selection of an anode-filter-tube voltage combination. Compared with Mo-Mo, both Mo-Rh and W-Rh gave good image quality of the mammary gland and a considerably lower absorbed dose. Mo-Rh-27 kVp is recommended for breast thicknesses of 60 mm or less; W-Rh-26 kVp, for breast thicknesses of greater than 60 mm.
The aim of this study was to compare the image quality of storage phosphor plates with that in screen-film radiograms in mammography. Two anode/filter combinations were also compared--Mo/Mo and W/Rh. S Storage phosphor plates, generation IIIN (Fuji, Tokyo, Japan) and a conventional screen-film system (Kodak, Rochester, N. Y.) were evaluated using two mammographic units. One unit had a 0.6-mm focal spot, an anode/filter combination of Mo/Mo and no grid (AMo); the other had a 0.3-mm focal spot, a grid, and two possible combinations of anode/filter Mo/Mo (BMo) and W/Rh (BW). Simulated tumours and microcalcifications were randomly positioned in an anthropomorphic breast phantom (RMI model 165, no. 210-009, Radiation Measurements Inc., Middleton, Wisconsin). The image quality was evaluated using a modified version of receiver operating characteristics analysis. Five observers evaluated 300 films and 300 hard copy images each. Radiation doses were also determined. The image quality of the conventional screen-film images was significantly better than that for the storage phosphor plate mammograms. The BMo system rated best, for the detection of both tumours and microcalcifications, although it was not significantly different from the BW system. Systems BMo and BW rated significantly better than the AMo system for both image receptors studied. The mean absorbed dose was twice as high for the BMo system as for the AMo and BW systems for both conventional and digital technique. The mammograms produced with the screen-film combination gave a significantly better detectability than the storage phosphor plates used in this study. Substantial dose reduction could be achieved using an anode/filter combination of W/Rh instead of Mo/Mo with no significant loss of information in the images.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.