Marine biotoxins pose a significant food safety risk when bioaccumulated in shellfish, and adequate testing for biotoxins in shellfish is required to ensure public safety and long-term viability of commercial shellfish markets. This report describes the use of a benchtop Orbitrap system for liquid chromatography-mass spectrometry (LC-MS) screening of multiple classes of biotoxins commonly found in shellfish. Lipophilic toxins such as dinophysistoxins, pectenotoxins, and azaspiracids were separated by reversed phase LC in less than 7 min prior to MS data acquisition at 2 Hz with alternating positive and negative scans. This approach resulted in mass accuracy for analytes detected in positive mode (gymnodimine, 13-desmethyl spirolide C, pectenotoxin-2, and azaspiracid-1, -2, and -3) of less than 1 ppm, while those analytes detected in negative mode (yessotoxin, okadaic acid, and dinophysistoxin-1 and -2) exhibited mass errors between 2 and 4 ppm. Hydrophilic toxins such as domoic acid, saxitoxin, and gonyautoxins were separated by hydrophilic interaction LC (HILIC) in less than 4 min, and MS data was collected at 1 Hz in positive mode, yielding mass accuracy of less than 1 ppm error at a resolving power of 100,000 for the analytes studied (m/z 300-500). Data were processed by extracting 5 ppm mass windows centered around the calculated masses of the analytes. Limits of detection (LOD) for the lipophilic toxins ranged from 0.041 to 0.10 μg/L (parts per billion) for the positive ions, 1.6-5.1 μg/L for those detected in negative mode, while the domoic acid and paralytic shellfish toxins yielded LODs ranging from 3.4 to 14 μg/L. Toxins were detected in mussel tissue extracts free of interference in all cases.
A liquid chromatography/mass spectrometry (LC/MS) method using nebulizer-assisted electrospray (ionspray) is described for the analysis of taxol and related taxane analogs in plant extracts from Taxus canadensis. The method used a reverse-phase liquid chromatography gradient elution which was entirely compatible with the operation of ionspray ionization. Abundant protonated molecules with limited fragmentation were obtained using this ionization technique, and provided adequate sensitivity for monitoring taxol in crude resin extracts. The LClMS method was evaluated for the analysis of taxol present at levels of 0.2% in resin extracts. Using selected-ion monitoring, the method provided detection limits of 50 ng/mL. In addition, other taxane analogs were identified in crude resin extracts using liquid chromatography combined with tandem mass spectrometry. Parent-ion scans for a fragment ion characteristic of the taxane nucleus provided the necessary selectivity and sensitivity for the identification of potentially active diterpenes in complex extracts.
Azaspiracids are neurotoxins produced by marine algae that have been detected in harvested mussels since 1995. They pose a significant threat to human health through the consumption of contaminated shellfish, and negatively impact the economy of areas where shellfish are harvested and processed. Regulatory agencies are beginning to advocate instrumental assays over traditional mouse bioassay methods. The development and validation of an assay method for AZA 1, the predominant azaspiracid toxin, and the production of a calibration standard and reference material will therefore be vital for quality control in monitoring laboratories worldwide. This report demonstrates a rapid and reproducible liquid chromatography/mass spectrometry (LC/MS) method for separation of all twelve known azaspiracids. Using a triple-quadrupole mass spectrometer, ultra-high sensitivity was obtained at the low-femtogram level injected on-column. At the same time, a linear response of three orders of magnitude was observed. We compared the results with those measured on an ion-trap mass spectrometer. The triple-quadrupole instrument was more sensitive, reliable and reproducible than the ion-trap instrument. The detection limit obtained on the ion-trap mass spectrometer was ten times higher than that obtained on the triple quadrupole. During the study, a new azaspiracid analog (AZA 7c) was discovered.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.