Polymers imprinted with clenbuterol were used to study the influence of various post-polymerization treatments [e.g., thermal annealing, microwave assisted extraction (MAE), Soxhlet extraction and supercritical fluid template desorption] on the bleeding of residual template. The aim of the study was to reduce the bleeding to levels that would allow the use of the materials as affinity phases for extraction of clenbuterol from bovine urine at concentrations below 1 ng ml-1. After treatment, the clenbuterol imprinted polymers were packed into solid-phase extraction columns and the bleeding was estimated by quantifying the amount of template released in 10 ml of methanol-acetic acid (9 + 1 v/v). This was followed by an assessment of selectivity and recovery in comparison with non-treated material. The lowest bleeding level was found after MAE using 100% trifluoroacetic acid for 3 x 20 min at 100 degrees C. The collected eluate contained in this case 3 ng ml-1 of clenbuterol. The same material was subsequently used for the extraction of clenbuterol from spiked bovine urine. The resulting selectivity and recovery were lower compared with those obtained using the untreated material. A milder but still efficient method to reduce the bleeding level was found to be MAE with formic acid. In this case a bleeding level of 14 ng ml-1 was found after only a 1 h extraction time. In a second model system, using a polymer imprinted with L-phenylalanine anilide, the bleeding was reduced to a similar level by extensive on-line washing in good swelling solvents containing acid or base additives and after thermal annealing of the polymers in the dry state.
A vancomycin chiral stationary phase (CSP) was fully evaluated in capillary electrochromatography (CEC) in reversed-phase and polar organic modes for a number of racemic pharmaceutical compounds. High efficiency and resolution values were obtained for a number of compound classes including thalidomide in both the polar organic mode (190000 plates meter(-1) and Rs = 13.8) and reversed-phase mode (125000 plates meter(-1) and Rs = 13.0). Experimental parameters, including organic modifier, organic solvent ratio, ionic strength, pH, temperature, and voltage, were examined in both the aqueous and nonaqueous modes to deduce their effect on the resultant EOF, retention times, resolution, and efficiency of chiral separations. All results were consistent with and found to be a combination of what is known from existing literature on CEC theory and experience obtained with macrocyclic antibiotic CSPs in LC. Column stability was excellent, and each column packed was found to offer repeatable separations even when switching from the aqueous to the nonaqueous mode.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.