A stability-indicating liquid chromatographic method has been developed and validated for the determination of Diltiazem Hydrochloride (DTZ) together with its six related substances (Diltiazem sulphoxide, Imp-A, Imp-B, Imp-D, Imp-E, and Imp-F) in a laboratory mixture as well as in a novel tablet formulation developed in-house. Efficient chromatographic separation was achieved on a Hypersil BDS C18 (150 mm×4.6 mm, 5.0 μm) with mobile phase containing 0.2% Triethylamine (TEA) in gradient combination with acetonitrile (ACN) at a flow rate of 1.0 mL/min and the eluent was monitored at 240 nm. In the developed method, the resolution of DTZ from any pair of impurities was found to be greater than 2.0. The test solution and related substances were found to be stable in the diluent for 24 h. The developed method resolved the drug from its known impurities, stated above, and also from additional impurities generated when the formulation was subjected to forced degradation; the mass balance was found close to 99.9%.Regression analyses indicate correlation coefficient value greater than 0.997 for DTZ and its six known impurities. The LOD for DTZ and the known impurities was at a level below 0.02%. The method has shown good, consistent recoveries for DTZ (99.8–101.2%) and also for its six known impurities (97.2–101.3%). The method was found to be accurate, precise, linear, specific, sensitive, rugged, robust, and stability-indicating.
A simple and robust analytical reversed-phase high-performance liquid chromatography method was developed and validated for simultaneous chromatographic elution of three cardiovascular drugs, namely clopidogrel, aspirin (ASP) and atorvastatin. The method was developed in rat plasma and dosage formulation with high-quality chromatographic separation between the drug peaks by using a stainless steel analytical column thermo beta-basic, C18 (25 × 0.46 cm, 5 µm). The system was operated at 25°C using a mobile phase consisting of acetonitrile and phosphate buffer (pH 3.0) in the gradient ratio at a flow rate of 1 mL min(-1) with ultraviolet detection monitored at 232 nm. The parametric statistics, i.e., correlation coefficient of 0.999, was assessed for all the drugs having linearity over the tested concentration range (10-10,000 ng mL(-1)) in rat plasma using an unweighted calibration curve. The accuracy of samples for six replicate measurements at lower limit of quantitation level was within limit. The method was applicable for the quality control of the mentioned drugs in raw material, bulk drug and pharmaceutical formulations as well as in pharmacokinetic studies.
Acitretin is a photosensitive oral retinoid with very limited data available on its degradation. The official HPLC method for acitretin determination was insufficient to resolve the degradation products generated during stability studies. Therefore, an isocratic RP-HPLC–UV method was developed for the determination of acitretin in the presence of its related impurities and degradation products. Efficient chromatographic separation was achieved on a Thermo beta-basic column C18 (100 mm×4.6 mm, 5 μm) with mobile phase containing 0.3% (v/v) glacial acetic acid with acetonitrile (ACN) and isopropyl alcohol (IPA) in an isocratic ratio of 70:30 at a flow rate of 1.0 mL/min with the eluent monitored at 360 nm. The method was validated for specificity, linearity, precision, accuracy and robustness. The calibration plot was linear over the concentration range of 50–150 μg/mL with a correlation coefficient (r2) of 0.999. The proposed method was used to investigate the degradation kinetics of acitretin under the different degradative conditions. The degradation rate constant (K), half-life (t1/2), and t90 were calculated. Degradation of acitretin followed pseudo-first-order kinetics. The drug was found to be less stable under acidic and photolytic degradation conditions: the photolytic degradation constants for acitretin in sunlight and UV light were 0.002698% and 0.0008402% min−1, respectively. The LOD for acitretin and the known impurities were at a level below 0.02%. The method shows consistent recoveries for ACTR (99.8%–101.2%) and also for its known impurities (97.2–101.3%). The method was found to be accurate, precise, linear, specific, sensitive, rugged, robust, and useful for characterizing the stability of this chemical.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.