A power-assisted exoskeleton should be capable of reducing the burden on the wearer’s body or rendering his or her work improved and efficient. More specifically, the exoskeleton should be easy to wear, be simple to use, and provide power assistance without hindering the wearer’s movement. Therefore, it is necessary to evaluate the backdrivability, range of motion, and power-assist capability of such an exoskeleton. This evaluation identifies the pros and cons of the exoskeleton, and it serves as the basis for its subsequent development. In this study, a lightweight upper-limb power-assisted exoskeleton with high backdrivability was developed. Moreover, a motion capture system was adopted to measure and analyze the workspace of the wearer’s upper limb after the exoskeleton was worn. The results were used to evaluate the exoskeleton’s ability to support the wearer’s movement. Furthermore, a small and compact three-axis force sensor was used for power assistance, and the effect of the power assistance was evaluated by means of measuring the wearer’s surface electromyography, force, and joint angle signals. Overall, the study showed that the exoskeleton could achieve power assistance and did not affect the wearer’s movements.
Brain-Machine Interface (BMI) has been considered as an effective way to help and support both the disabled rehabilitation and healthy individuals’ daily lives to use their brain activity information instead of their bodies. In order to reduce costs and control exoskeleton robots better, we aim to estimate the necessary torque information for a subject from his/her electroencephalography (EEG) signals when using an exoskeleton robot to perform the power assistance of the upper limb without using external torque sensors nor electromyography (EMG) sensors. In this paper, we focus on extracting the motion-relevant EEG signals’ features of the shoulder joint, which is the most complex joint in the human’s body, to construct a power assistance system using wearable upper limb exoskeleton robots with BMI technology. We extract the characteristic EEG signals when the shoulder joint is doing flexion and extension movement freely which are the main motions of the shoulder joint needed to be assisted. Independent component analysis (ICA) is used to extract the source information of neural components, and then the average method is used to extract the characteristic signals that are fundamental to achieve the control. The proposed approach has been experimentally verified. The results show that EEG signals begin to increase at 300–400 ms before the motion and then decrease at the beginning of the generation of EMG signals, and the peaks appear at about one second after the motion. At the same time, we also confirmed the relationship between the change of EMG signals and the EEG signals on the time dimension, and these results also provide a theoretical basis for the delay parameter in the linear model which will be used to estimate the necessary torque information in future. Our results suggest that the estimation of torque information based on EEG signals is feasible, and demonstrate the potential of using EEG signals via the control of brain-machine interface to support human activities continuously.
Brain–Machine Interfaces (BMIs) have attracted much attention in recent decades, mainly for their applications involving severely disabled people. Recently, research has been directed at enhancing the ability of healthy people by connecting their brains to external devices. However, there are currently no successful research reports focused on robotic power augmentation using electroencephalography (EEG) signals for the shoulder joint. In this study, a method is proposed to estimate the shoulder’s electromyography (EMG) signals from EEG signals based on the concept of a virtual flexor–extensor muscle. In addition, the EMG signal of the deltoid muscle is used as the virtual EMG signal to establish the EMG estimation model and evaluate the experimental results. Thus, the shoulder’s power can be augmented by estimated virtual EMG signals for the people wearing an EMG-based power augmentation exoskeleton robot. The estimated EMG signal is expressed via a linear combination of the features of EEG signals extracted by Independent Component Analysis, Short-time Fourier Transform, and Principal Component Analysis. The proposed method was verified experimentally, and the average of the estimation correlation coefficient across different subjects was 0.78 (±0.037). These results demonstrate the feasibility and potential of using EEG signals to provide power augmentation through BMI technology.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.