Background Various surface treatment options have been adopted with the aim to improve osseointegration, reducing the overall treatment time. Implant stability of early loaded implants with different modified surfaces was compared in the present study. Methods Patients were selected from the Department of Oro-Maxillofacial Surgery and Stomatology at Semmelweis University. Patients randomly received SA (alumina sandblasted and acid-etched), NH (bioabsorbable apatite nanocoating) or SLA (large-grit sandblasted and acid-etched) surface implants. Outcome measures were: implant success, implant stability, and periodontal parameters. The implant stability was measured at the time of implant placement (primary stability) and six weeks after (prothesis delivery, secondary stability). Osstell and Periotest were applied to take all the measurements. The primary and secondary stability were compared in the three study groups Finally the periimplant probing depth appearing after three months of loading was checked on 6 points around to the implant-supported prostheses. Shapiro–Wilk and Mann–Whitney tests were used for the comparison between the study groups. Results A total of 75 implants with different length and diameter were inserted into various positions. One implant failed spontaneously at the fourth week after implant placement. The survival rate was 98,7%. Comparing the primary and secondary stability values, the data were significantly improved in every groups. The difference was the highest in the NH group, however, this difference was not significant compared to the two other groups. Good periodontal parameters were experienced in all the tested implants, independently by the groups. Conclusions With the limitation of the present study, all the implants showed improved stability six weeks after implant placement. A trend of higher result was found for the NH group. Further studies with longer follow-up are needed to confirm this preliminary results. Trial registration: Current Controlled Trials ISRCTN13181677; the date of registration: 04/03/2021. Retrospectively registered.
The early loading of different surface treated dental implants is compared in our clinical study. Patients were selected from the outpatient ward of the Department of Oro-Maxillofacial Surgery and Stomatology at the Semmelweis University. The secondary stability, that evolved after 6 weeks of healing, was measured on acid etched/sand blasted (SLA) and bio-hydroxyapatite coated implants. Osstell® and Periotest® were applied to determine this value. Periodontal probing depth appearing after 3 months of loading was checked on 6 points next to the implant supported prosthesis. Shapiro-Wilk and Mann-Whitney tests have been chosen to fulfil the statistical analysis. According to our results, a similar satisfying secondary stability can be obtained independently of the modality of the surface. The values were higher in the bio-hydroxyapatite group; however, this difference was not significant. The outcome of measuring the probing depth reflects the importance of frequent recalls of patients. The necessary ethical approval for our study has been provided by the National Institute of Pharmacy and Nutrition (reference number: OGYÉI/55197/2019 ).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.