Alternative paradigm for spatial and fibre-type selective vagus nerve stimulation (VNS) was developed using realistic structural topography and tested in an isolated segment of a porcine cervical left vagus nerve (LVN). A spiral cuff (cuff) containing a matrix of ninety-nine electrodes was developed for selective VNS. A quasitrapezoidal stimulating pulse (stimulus) was applied to the LVN via an appointed group of three electrodes (triplet). The triplet and stimulus were configured to predominantly stimulate the B-fibres, minimizing stimulation of the A-fibres and by-passing the stimulation of the C-fibres. To assess which fibres made the most probable contribution to the neural response (NR) during selective VNS, the distribution of conduction velocity (CV) within the LVN was considered. Experimental testing of the paradigm showed the existence of certain parameters and waveforms of the stimulus, for which the contribution of the A-fibres to the NR was slightly reduced and that of the B-fibres was slightly enlarged. The cuff provided satisfactory fascicle discrimination in selective VNS as well as satisfactory fascicle discrimination during NR recording. However, in the present stage of development, fibre-type VNS remained rather limited.
In this study, the electrochemical performance of platinum electrodes within a multi-electrode spiral cuff to be used for selective nerve stimulation was investigated. The original cuff, simplified into a half-cuff, contained a single row of nine electrodes (0.5 × 2 mm) at a distance of 2 mm from its inner surface. Cyclic voltammetry was used to investigate the electrochemical reactions at the electrode-electrolyte interface, to define a potential window within which the electrode could be safely used in selective nerve stimulation, to calculate the charge injection capacity and cathodal charge storage capacity. Voltage transients retrieved during excitation with quasitrapezoidal biphasic current pulses, tested by selective nerve stimulation of the isolated porcine left cervical vagus nerve segment, were used to determine the maximum polarization across the electrode-electrolyte interface and to calculate cathodic charge injection capacity of the electrode. The results show that the most negative and most positive potentials across the electrode-electrolyte interface reached -0.54 and 0.59 V; these did not exceed the safe potential limits for water electrolysis. Furthermore, the time integral of the cathodic current by cyclic voltammetry measured over the potential range of water electrolysis, actually representing the cathodal charge storage capacity, was approximately -4 mC cm(-2). The charge injection capacity, representing the maximum charge density injected in a current stimulation pulse, using only reversible processes, however, was around 75 µC cm(-2). In conclusion, both, the tested stimulation pulse and electrode are suitable for efficient and safe selective nerve stimulation.
This article reviews an improved methodology and technology for crafting a multi-electrode spiral cuff for the selective activation of nerve fibres in particular superficial regions of a peripheral nerve. The analysis, structural and mechanical properties of the spot welds used for the interconnections between the stimulating electrodes and stainless-steel lead wires are presented. The cuff consisted of 33 platinum electrodes embedded within a self-curling 17-mm-long silicone spiral sheet with a nominal internal diameter of 2.5 mm. The weld was analyzed using scanning electron microscopy and nanohardness tests, while the interconnection was investigated using destructive load tests. The functionality of the cuff was tested in an isolated porcine vagus nerve. The results of the scanning electron microscopy show good alloying and none of the typical welding defects that occur between the wire and the platinum foil. The results of the destructive load tests show that the breaking loads were between 3.22 and 5 N. The results of the nanohardness testing show that the hardness of the weld was different for the particular sites on the weld sample. Finally, the results of the functional testing show that for different stimulation intensities both the compound action potential deflection and the shape are modulated.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.