A speckle-based method for the X-ray crystal diffraction wavefront measurement is implemented, and the slope errors of channel-cut crystals with different surface characteristics are measured. The method uses a speckle scanning technique generated by a scattering membrane translated using a piezo motor to infer the deflection of X-rays from the crystals. The method provides a high angular sensitivity of the channel-cut crystal slopes in both the tangential and sagittal directions. The experimental results show that the slope error of different cutting and etching processes ranges from 0.25 to 2.98 μrad. Furthermore, the results of wavefront deformation are brought into the beamline for simulation. This method opens up possibilities for new high-resolution applications for X-ray crystal diffraction wavefront measurement and provides feedback to crystal manufacturers to improve channel-cut fabrication.
A novel, asymmetrically cut, channel-cut crystal was designed and manufactured with the aim to significantly reduce the beam offset change during energy scans. The improvement was verified with synchrotron radiation from an undulator source. The importance of even small, generally so far neglected, asymmetries is pointed out for high-accuracy monochromators.
Crystal monochromators are indispensable optical components for the majority of beamlines at synchrotron radiation facilities. Channel-cut monochromators are sometimes chosen to filter monochromatic X-ray beams by virtue of their ultrahigh angular stability. Nevertheless, high-accuracy polishing on the inner diffracting surfaces remains challenging, thus hampering their performance in preserving the coherence or wavefront of the photon beam. Herein, a magnetically controlled chemical–mechanical polishing (MC-CMP) approach has been successfully developed for fine polishing of the inner surfaces of channel-cut crystals. This MC-CMP process relieves the constraints of narrow working space dictated by small offset requirements and achieves near-perfect polishing on the surface of the crystals. Using this method, a high-quality surface with roughness of 0.614 nm (root mean square, r.m.s.) is obtained in a channel-cut crystal with 7 mm gap designed for beamlines at the High Energy Photon Source, a fourth-generation synchrotron radiation source under construction. On-line X-ray topography and rocking-curve measurements indicate that the stress residual layer on the crystal surface was removed. Firstly, the measured rocking-curve width is in good agreement with the theoretical value. Secondly, the peak reflectivity is very close to theoretical values. Thirdly, topographic images of the optics after polishing were uniform without any speckle or scratches. Only a nearly 2.5 nm-thick SiO2 layer was observed on the perfect crystalline matrix from high-resolution transmission electron microscopy photographs, indicating that the structure of the bulk material is defect- and dislocation-free. Future development of MC-CMP is promising for fabricating wavefront-preserving and ultra-stable channel-cut monochromators, which are crucial to exploit the merits of fourth-generation synchrotron radiation sources or hard X-ray free-electron lasers.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.