X-ray mapping by EDS techniques of rough samples or samples with a complex topographic surface is more difficult than mapping relatively smooth surfaces. The problem of the sample with a rough surface arises because a lower intensity of an element, or even no intensity, can either mean the absence of that element or it can mean the element has a significant presence but the area can not be "viewed" by the EDS detector (Fig. 1). This problem or ambiguity can be partially solved by the use of a second detector which would ideally have an opposing view. The use of a second detector still presents some problems of interpretation in that there is a contrast artifact arising from the fact that some areas of the sample produce x rays which can be received by both detectors, while the x rays from other areas are detected by only one or by neither of the two detectors [1]. This artifact originates from the simple summing of the x rays from the two detectors (Fig. 1c). A method is presented that can work around this problem and will provide a better interpretation of the chemical variability within the sample.When two detectors are used each detector will have its own spectral map dataset or data cube and the two datasets are merged in a variety of ways to produce a third dataset. The merging can be done by the summing or averaging of the spectral data at each pixel (Fig. 1c). A preferred method would be to merge only the spectral information from the detector that had the most counts at each pixel and to ignore the counts from the detector that had a lower, or a much lower intensity (Fig. 1d). Although it might seem counter-intuitive that some data should be discarded, this eliminates most of the problem of the contrast artifact and will tend to equalize the contrast between areas that are able to have x rays counted by both detectors as compared to those areas where the x rays are seen by only one detector. The contrast artifact is often greatly diminished but not completely eliminated by selecting the information from the detector with the maximum intensity. The chemical contrast may be enhanced as compared to topographic effects by an additional normalization step. The normalization procedure that has been used to a positive effect is a full quantification (ZAF Wt. %) of the merged map data (Fig. 2).There is still a need to either eliminate the data for the pixels that are shadowed in the view of both detectors or to indicate in some way that the data in the maps for these regions are not reliable (note the noisy data in Fig. 2a from some of the voids). A map can be created from the summing of all counts of all energies on a pixel by pixel basis for each detector and these maps can be summed for the 2 detector case. Dark areas of this map represent areas in the shadow of both detectors. If the map is inverted and rendered as a binary image, it can be used as an overlay against a single map or with several maps (Figs. 1 and 2) and the "null" areas where no x rays are detected will be shown in white. When overlain with ...
Extended abstract of a paper presented at Microscopy and Microanalysis 2013 in Indianapolis, Indiana, USA, August 4 – August 8, 2013.
Extended abstract of a paper presented at Microscopy and Microanalysis 2012 in Phoenix, Arizona, USA, July 29 – August 2, 2012.
Electron microscopy and x-ray microanalysis are common techniques in many research, development and quality labs (Garratt-Reed and Bell, 2002; Goldstein et al., 2003). As systems become ever more automated, as well as easy to use, new applications for the use of these systems develop and expand. One such application is particle analysis. These “particles” might be small loose fragments that can be applied to a conductive adhesive or a filter, embedded in epoxy and polished, or they can be inclusions within collect an EDS spectrum.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.