A 72-year-old man who had phacoemulsification with implantation of an Akreos Adapt Advanced Optics (AO) IOL in the left eye complained of blurring vision 4 months postoperatively. Multiple fine white granules were found within the IOL. Intraocular lens exchange was performed at 7 months, and the explanted IOL was sent for histopathological analysis. Diffuse fine white granules were seen within the explanted IOL material just beneath the surface; they were stained positive by alizarin red and the von Kossa method. Scanning electron microscopy confirmed the presence of calcium deposits in the IOL material. Blood and aqueous were drawn from the patient for biochemical analysis, and the results were normal. We believe this is the first clinicopathological report of calcification of the Akreos Adapt AO IOL.
Increasing incidence of malignant eyelid tumors was noticed in Hong Kong from 1997 to 2009, with BCC dominating the incidence trend. Recurrence after complete surgical excision was uncommon.
Objective: To describe a novel approach to measuring anterior chamber angle dimensions and configurations.Methods: Sixty-nine images were selected randomly from the ultrasound biomicroscopic image database to develop the algorithm. Thirty images were selected for further analyses. The value of each pixel of the 8-bit grayscale ultrasound biomicroscopic images was quantized into 0 (black) or 1 (white), and the edge points outlining the angle were detected and fitted with straight lines. The dimensions and profiles of anterior chamber angles were then measured.
Results:The algorithm failed to identify the edge points correctly in 8 (11.6%) of 69 images because of strong background noise. Three basic types of angle configuration were identified based on the derived angle profiles: constant, increasing, and decreasing, which corresponded to flat, bowed forward, and bowed backward iris contours, respectively. The angle measurements demonstrated high correlation with trabecular-iris angle and angle opening distance 500 (calculated as the distance from the corneal endothelium to the anterior iris surface perpendicular to a line drawn at 500 µm from the scleral spur). The strongest association was found between the averaged angle derived from the angle profile and the angle opening distance 500 (r =0.91).
This is the first article that demonstrated a detectable level of serum gentamicin level after usage of topical eyedrops. This is also the first article demonstrating that nephrotoxicity of topical fortified gentamicin and vancomycin eyedrops was found. The acute renal failure in our patient recovered completely after cessation of the eyedrops.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations –citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.