The objective of this study is to present a new coupling method in order to measure the electrical properties of titanium alloy pedicle screws used in spinal surgery and to compare it with other common methods of measurement. An experimental setup was devised to test the electrical resistance of two specimens of pedicle screws using four methods for coupling the sensing leads, including the use of multimeter probes, alligator clips, wrapped wires and encapsulation with thermo-retractable sleeves. The electrical resistance of the pedicle screw under testing was measured at a current of 10 mA for each coupling method, and the results compared. Our findings show that although widely used in electrical analysis, the alligator clips do not perform as well as the other methods, such as simple wrapping of wires around the screw or the direct application of multimeter probes. The use of thermo-retractable sleeves provides the lowest resistance and inter-quartile range and is closer to the tabled values for the screw’s titanium alloy. Additionally, only this method allows the measurement of identical resistivity values between different screw models manufactured with the same titanium alloy. We then concluded that the use of wrapped wires encapsulated with thermo-retractable sleeves allow more accurate measurements of the pedicle screw’s electrical properties.
The purpose of this study was to investigate if the use of an ankle foot orthosis in passive mode (without actuation) could modify minimum foot clearance, and if there are any compensatory mechanisms to enable these changes during treadmill gait at a constant speed. Eight participants walked on an instrumented treadmill without and with an ankle foot orthosis on the dominant limb at speeds of 0.8, 1.2, and 1.6 km/h. For each gait cycle, the minimum foot clearance and some gait linear kinematic parameters were calculated by an inertial motion capture system. Additionally, maximum hip and knee flexion and maximum ankle plantar flexion were calculated. There were no significant differences in the minimum foot clearance between gait conditions and lower limbs. However, differences were found in the swing, stance and step times between gait conditions, as well as between limbs during gait with orthosis (p < 0.05). An increase in hip flexion during gait with orthosis was observed for all speeds, and different ankle ranges of motion were observed according to speed (p < 0.05). Thus, the use of an ankle foot orthosis in passive mode does not significantly hinder minimum foot clearance, but can change gait linear and angular parameters in non-pathological individuals.
Human postural control is a fundamental ability for static and dynamic tasks, especially in hiper- and hipo-functional populations, such as the elderly. The Equimetrix is a clinical device developed to assess both the base of support (BoS) and the center of mass (CoM) dynamics, thus allowing their use as new evaluation and training tools. This study aims to perform a criteria based validation of Equimetrix by comparing the BoS and CoM data with gold-standard equipment. A motion capture system, force platform, and pressure mat were used to calculate the CoM, center of pressure (CoP) and BoS during bipedal, unipedal, feet together and full tandem stances. Results demonstrate an excellent reliability of Equimetrix in terms of spatial accuracy of the CoM, although over-estimating the CoM height. Differences were found when comparing Mean velocity Path with the CoM, but not with the CoP, indicating a lower reliability in time-based parameters. The Equimetrix presents a tendency to overestimate the BoS, with mixed reliability values, which may be related to the different size of sensing elements between the Equimetrix and the pressure sensing mat. These are encouraging results that should be further explored during dynamic tasks.
O Laboratório de Biomecânica do Porto (LABIOMEP-UP) é um centro de competências da Universidade do Porto dedicado ao ensino, investigação científica e tecnológica, inovação, prestação de serviços técnicos especializados e transferência de conhecimento e tecnologia em Biomecânica (humana e animal) de interesse ergonómico, clínico, desportivo ou biomimético (ex: design, animação computacional e desenvolvimento de modelos). A missão do LABIOMEP-UP é catalisar o potencial de crescimento e vantagem competitiva da Universidade do Porto em todos os domínios direta ou indiretamente relacionados com a Biomecânica, incluindo a interação com o tecido industrial e comercial.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.