The ability to fabricate sensory systems capable of highly selective operation in complex fluid will undoubtedly underpin key future developments in healthcare. However, the abundance of (bio)molecules in these samples can significantly impede performance at the transducing interface where nonspecific adsorption (fouling) can both block specific signal (reducing sensitivity) and greatly reduce assay specificity. Herein, we aim to provide a comprehensive review discussing concepts and recent advances in the construction of antifouling sensors that are, through the use of chemical, physical, or biological engineering, capable of operating in complex sample matrix (e.g., serum). We specifically highlight a range of molecular approaches to the construction of solid sensory interfaces (planar and nanoparticulate) and their characterization and performance in diverse in vitro and in vivo analyte (e.g., proteins, nucleic acids, cells, neuronal transmitters) detection applications via derived selective optical or electrochemical strategies. We specifically highlight those sensors that are capable of detection in complex media or those based on novel architectures/approaches. Finally, we provide perspectives on future developments in this rapidly evolving field.
ObjectiveParkinson’s disease is characterised neuropathologically by α-synuclein aggregation. Currently, there is no blood test to predict the underlying pathology or distinguish Parkinson’s from atypical parkinsonian syndromes. We assessed the clinical utility of serum neuronal exosomes as biomarkers across the spectrum of Parkinson’s disease, multiple system atrophy and other proteinopathies.MethodsWe performed a cross-sectional study of 664 serum samples from the Oxford, Kiel and Brescia cohorts consisting of individuals with rapid eye movement sleep behavioural disorder, Parkinson’s disease, dementia with Lewy bodies, multiple system atrophy, frontotemporal dementia, progressive supranuclear palsy, corticobasal syndrome and controls. Longitudinal samples were analysed from Parkinson’s and control individuals. We developed poly(carboxybetaine-methacrylate) coated beads to isolate L1 cell adhesion molecule (L1CAM)-positive extracellular vesicles with characteristics of exosomes and used mass spectrometry or multiplexed electrochemiluminescence to measure exosomal proteins.ResultsMean neuron-derived exosomal α-synuclein was increased by twofold in prodromal and clinical Parkinson’s disease when compared with multiple system atrophy, controls or other neurodegenerative diseases. With 314 subjects in the training group and 105 in the validation group, exosomal α-synuclein exhibited a consistent performance (AUC=0.86) in separating clinical Parkinson’s disease from controls across populations. Exosomal clusterin was elevated in subjects with non-α-synuclein proteinopathies. Combined neuron-derived exosomal α-synuclein and clusterin measurement predicted Parkinson’s disease from other proteinopathies with AUC=0.98 and from multiple system atrophy with AUC=0.94. Longitudinal sample analysis showed that exosomal α-synuclein remains stably elevated with Parkinson’s disease progression.ConclusionsIncreased α-synuclein egress in serum neuronal exosomes precedes the diagnosis of Parkinson’s disease, persists with disease progression and in combination with clusterin predicts and differentiates Parkinson’s disease from atypical parkinsonism.
Anions play a vital role in a broad range of environmental, technological, and physiological processes, making their detection/quantification valuable. Electroanalytical sensors offer much to the selective, sensitive, cheap, portable, and real-time analysis of anion presence where suitable combinations of selective (noncovalent) recognition and transduction can be integrated. Spurred on by significant developments in anion supramolecular chemistry, electrochemical anion sensing has received considerable attention in the past two decades. In this review, we provide a detailed overview of all electroanalytical techniques that have been used for this purpose, including voltammetric, impedimetric, capacititive, and potentiometric methods. We will confine our discussion to sensors that are based on synthetic anion receptors with a specific focus on reversible, noncovalent interactions, in particular, hydrogen-and halogen-bonding. Apart from their sensory properties, we will also discuss how electrochemical techniques can be used to study anion recognition processes (e.g., binding constant determination) and will furthermore provide a detailed outlook over future efforts and promising new avenues in this field.
A physical hydrogel cross-linked via the host-guest interactions of cucurbit[8]uril and utilised as an implantable drug-delivery vehicle for the brain is described herein. Constructed from hyaluronic acid, this hydrogel is biocompatible and has a high water content of 98%. The mechanical properties have been characterised by rheology and compared with the modulus of human brain tissue demonstrating the production of a soft material that can be moulded into the cavity it is implanted into following surgical resection. Furthermore, effective delivery of therapeutic compounds and antibodies to primary human glioblastoma cell lines is showcased by a variety of in vitro and ex vivo viability and immunocytochemistry based assays.
Sigma-hole interactions, in particular halogen bonding (XB) and chalcogen bonding (ChB), have become indispensible tools in supramolecular chemistry, with wide-ranging applications in crystal engineering, catalysis and materials chemistry as well...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.