Summary. The objective of this study was to develop and validate an assay method for simultaneous determination of atenolol, furosemide, losartan, and spironolactone in pharmaceutical formulations. A reverse-phase high-performance liquid chromatography procedure was developed, using a Kinetex ® C-18 column (100 mm × 4.6 mm, 2.6 µm). The mobile phase was composed of methanol-water (75:25 v/v, pH 3.0, adjusted with phosphoric acid), with a flow rate of 0.4 mL min −1 . All drugs were separated in less than 5 min. The method was validated according to International Conference on Harmonization (ICH) and Association of Official Analytical Chemists (AOAC) guidelines. The method showed linearity in a concentration range of 0.75-12.0 µg mL −1 for atenolol (r = 0.9995), 0.30-12.00 µg mL −1 for furosemide (r = 0.9997), 0.45-12.00 µg mL −1 for losartan (r = 0.9995), and 0.45-12.0 µg mL −1 for spironolactone (r = 0.9999). The method also showed repeatability and precision. The three-day average intra-day precisions were 101.35 ± 0.74% for atenolol, 95.84 ± 1.44% for furosemide, 98.90 ± 1.16% for losartan, and 97.19 ± 0.18% for spironolactone. Similarly, the inter-day precisions were 101.34 ± 0.72% for atenolol, 95.84 ± 0.1.50% for furosemide, 98.90 ± 1.17% for losartan, and 97.19 ± 0.83% for spironolactone. The method accuracy was also tested and validated -in this case, the average recovery values were 100.18 ± 1.20% for atenolol, 99.83 ± 1.54% for furosemide, 100.07 ± 0.95% for losartan, and 99.94 ± 0.93% for spironolactone. Finally, the method was successfully applied in the simultaneous determination of atenolol, furosemide, losartan, and spironolactone in magisterial formulas, as well as in commercial pharmaceutical formulations.