Background factors and ophthalmic findings are similar to those that have been reported previously, including relatively stable findings even after a long observation and the occurrence of central serous chorioretinopathy and choroidal neovascularization. Bilateral cases are not rare in the current cohort, and choroidal vascular hyperpermeability is frequently observed in indocyanine green angiography, suggesting there were choroidal hemodynamic changes around the excavation.
This case-control study reports the association between nutrient intake and neovascular age-related macular degeneration (AMD) in Japan. The nutrient intake of 161 neovascular AMD cases from two university hospitals and 369 population-based control subjects from a cohort study was assessed using a brief-type self-administered questionnaire on diet history, which required respondent recall of the usual intake of 58 foods during the preceding month. Energy-adjusted nutrient intake values were compared between the groups. Logistic regression analysis was used to estimate odds ratios (ORs) and 95% CIs adjusted for smoking history, age, sex, chronic disease history, supplement use, and alcohol consumption. Logistic regression analysis demonstrated that low intakes of n-3 fatty acid, α-tocopherol, zinc, vitamin D, vitamin C, and β-carotene were associated with neovascular AMD (Trend P < 0.0001 for n-3 fatty acid, Trend P < 0.0001 for α-tocopherol, Trend P < 0.0001 for zinc, Trend P = 0.002 for vitamin D, Trend P = 0.04 for vitamin C, Trend P = 0.0004 for β-carotene). There was no association with retinol or cryptoxanthin intake and neovascular AMD (P = 0.67, 0.06).
PurposeThe purpose of the current study is to investigate the test-retest reproducibility of visual fields (VFs) measured with the MP-3 microperimeter, in patients with retinitis pigmentosa (RP).MethodVFs were twice measured with the MP-3 and also the Humphrey Field Analyzer, using the 10–2 test grid pattern in both perimeters, in 30 eyes (15 right and 15 left eyes) of 18 RP patients (11 males and 7 females). Test-retest reproducibility was assessed using the mean absolute deviation (MAD) measure at all 68 points in the test grid. Reproducibility was also evaluated using the intraclass correlation coefficient (ICC) of VF sensitivities.ResultThe mean sensitivity measured in the HFA 10–2 was significantly higher than that measured in the MP-3 in both the first and second VF tests (p <0.0001, linear mixed model). The MAD was 2.4±0.6 [1.1 to 3.6] dB for MP-3 and 2.4±0.9 [1.1 to 5.1] dB for HFA 10–2, which was not significantly different (p = 0.76, linear mixed model). The ICC value associated with the MP-3 VFs was 0.81±0.13 [0.49 to 0.98], which was significantly larger than that observed for the HFA 10–2 VFs: 0.77±0.19 [0.20 to 0.94] (p = 0.043, linear mixed model).ConclusionThe MP-3 microperimeter appears to be useful to evaluate central visual function in RP eyes, exhibiting test-retest reproducibility that is equal to, or better than, that observed in HFA 10–2 VFs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.