In the northern part of Greece, close to the city of Kavala, a phosphoric acid production industry has operated since 1965. The raw material used is the phosphate rock imported from the foreign countries. During industrial processes, naturally occurring radioactive materials (NORM) deposits exist in many facilities in the industry, causing increased levels of radiation exposure. Additionally, increased levels of NORM concentrations are also detected in the waste material of the production process, the phosphogypsum. According to the Greek Regulations for Radiation Protection (no. 216B, 5/3/2001), which is in accordance with the 96/29/EURATOM 31/5/1996, the action levels concerning the effective dose to workers at workplaces due to natural radiation sources are 1 mSv y(-1). Work activities where the corresponding doses exceed 6 mSv y(-1) are under the control of the Greek Atomic Energy Commission (GAEC). The mean yearly radon concentration action level at workplaces is 400 Bq m(-3), while the corresponding concentration limit is 3000 Bq m(-3), respectively. GAEC, according to its constitutional law, is the responsible organisation to enforce and to implement the law by means of in situ surveys and laboratory measurements. The first inspection of the area was performed in 2002 and the first measures were proposed. Periodic inspections were performed every 2 y in order to extend the operation licensing of the industry. In this work a dose assessment of the workers based on in situ and laboratory measurements is presented. In order to assess the doses to the workers the external and the internal doses are estimated.
Spectroscopic measurements are presented using the PID350 pixelated gamma radiation detectors. A high-speed data acquisition system has been developed in order to reduce the data loss during the data reading in case of a high flux of photons. A data analysis framework has been developed in order to improve the resolution of the acquired energy spectra, using specific calibration parameters for each PID350's pixel. Three PID350 detectors have been used to construct a stacked prototype system and spectroscopic measurements have been performed in order to test the ability of the prototype to localize radioactive sources.
Simulation studies and spectroscopic measurements are presented regarding the development of a pixel multilayer CdTe detector under development in the context of the COCAE project. The instrument will be used for the localization and identification of radioactive sources and radioactively contaminated spots. For the localization task the Compton effect is exploited. The detector response under different radiation fields as well as the overall efficiency of the detector has been evaluated. Spectroscopic measurements have been performed to evaluate the energy resolution of the detector. The efficiency of the event reconstruction has been studied in a wide range of initial photon energies by exploiting the detector's angular resolution measure distribution. Furthermore, the ability of the COCAE detector to localize radioactive sources has been investigated.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.