This study compares the visual and refractive performance of the TECNIS Synergy (DFR00V-DFW150-225-300-375) multifocal intraocular lens (IOL) and the AcrySof IQ PanOptix (TFAT00-30-40-50-60) multifocal IOL. Patients who underwent phacoemulsification and cataract extraction and received either a multifocal Synergy or PanOptix IOL were included. Monocular uncorrected distance (UDVA), intermediate (UIVA), near (UNVA), and corrected distance (CDVA) visual acuities were assessed at three and six months postoperatively. Secondary outcome measures of photic phenomena were also assessed. A total of 140 patients (224 eyes) were included in this study, with 69 patients (105 eyes) in the Synergy group and 71 patients (119 eyes) in the PanOptix group. There were no statistically significant differences in UIVA or CDVA measurements across all time points. When assessing UDVA, at three months postoperatively, there were more eyes in the PanOptix group with vision better than 20/40 (p = 0.04). At three and six months postoperatively, the average UNVA was superior in the Synergy group (p = 0.01, 0.002). While the Synergy group reported more night vision disturbances at one and three months (p = 0.01, 0.03), the PanOptix group had more night vision disturbances at six months (p = 0.02). Although not statistically significant, the AcrySof IQ PanOptix multifocal IOL demonstrated better UDVA and UIVA sooner postoperatively than the TECNIS Synergy multifocal IOL. The Synergy IOL provided statistically better UNVA compared to the PanOptix IOL at three and six months postoperatively. Synergy patients reported more early photic phenomena than PanOptix patients, which later diminished.
Purpose To evaluate 10 years of KAMRA corneal inlay explantation and associated visual outcomes. Patients and Methods Single-site retrospective chart review of 22 cases of AcuFocus KAMRA Inlay (ACI7000PDT) explantation (range 1 week–1 year). Uncorrected distance visual acuity (UDVA), uncorrected near visual acuity (UNVA), corrected distance visual acuity (CDVA), and manifest refraction at 1 day, 1 week, 1 month, 3 months, 6 months, and 1 year post-explantation were reviewed. Results The explantation rate was 8.2% across 10 years. All patients underwent KAMRA explantation due to dissatisfaction with their vision including blurry near vision, impaired night vision, decreased vision in dim lighting, streaks or halos, haze, and double vision. Mean UDVA pre-implant was −0.01±0.13 logMAR (logarithm of the minimal angle of resolution), 0.30±0.22 logMAR pre-explant, and 0.16±0.15 logMAR post-explant (n=20). Mean UNVA pre-implant was 0.37±0.09 logMAR, 0.38±0.13 logMAR pre-explant, and 0.42±0.21 logMAR post-explant (n=20). Mean CDVA pre-implant was −0.01±0.04 logMAR and 0.05±0.11 logMAR post-explant (n=17). Mean CDVA pre-explant was 0.04±0.07 logMAR and 0.04±0.11 logMAR post-explant (n=19). Significant differences were observed between pre-implant and post-explant UDVA (p=0.009), and between pre-explant and post-explant UDVA (p=0.02). All patients (100%) had 20/20 or better CDVA pre-implant but decreased to 73.7% post-explant. Sixty percent (12/20) of the patients lost UDVA Snellen acuity lines post-explant. MRSE was −0.31±0.29 D pre-implant and +0.26±0.77 D post-explant (p=0.007) with note of a hyperopic shift. The hyperopic shift in 31.6% (6/19) of patients did not resolve after explantation. Post-explant residual corneal haze occurred in 72.7% (16/22) of patients. Conclusion Although the KAMRA corneal inlay is a removable device, patients may experience residual corneal haze, hyperopic shift, and deficits in UDVA after explantation compared to pre-implantation UDVA.
To determine rates of enhancement and visual prognosis following photorefractive keratectomy (PRK) enhancement of small-incision lenticule extraction (SMILE). Patients and Methods: This retrospective, single-site study reviewed all cases of primary SMILE at Hoopes Vision in Draper, Utah between March 14, 2017 and April 8, 2022 to identify any cases that required follow-up enhancement. Primary SMILE was performed using Visumax 500 kHz femtosecond laser (Carl Zeiss Meditec, Jena, Germany). All enhancements were performed with alcoholassisted PRK, using a WaveLight EX500 excimer laser (Alcon Laboratories, Inc., Fort Worth, TX). Results: Four hundred and five eyes underwent primary SMILE, of which 15 later underwent PRK enhancement (enhancement rate of 3.7%). No significant difference in pre-SMILE data was identified between the enhancement and non-enhancement groups. The average age of those who underwent PRK enhancement was 33.8±6.3 years old and ranged from 25 to 45. Following primary SMILE, 13 eyes (87%) had an uncorrected distance visual acuity (UDVA) of 20/40 or better, and none had a UDVA of 20/20 or better. After one year of post-enhancement follow-up, all eyes had a UDVA of 20/40 or better, and 13 eyes (87%) had a UDVA of 20/20 or better (Figure 1). All were within one diopter of target spherical equivalent (SEQ), 13 (87%) were within 0.50 D, and 10 (67%) were within 0.25 D. Of those with 12-month follow-up data, none had UDVA worse than corrected distance visual acuity (CDVA), and none had lost lines of CDVA. Efficacy and safety indices were 1.03 and 0.99, respectively. Conclusion: Following SMILE, ophthalmologists may anticipate an enhancement rate of one to seven percent. In these cases, PRK is a safe and effective procedure for enhancement of SMILE.
Purpose To analyze refractive changes after neodymium: yttrium-aluminum-garnet (Nd:YAG) posterior capsulotomy in pseudophakic eyes. Patients and Methods Patients who underwent Nd:YAG capsulotomy after cataract surgery from January 2013 to April 2022 were included in this retrospective study. Sphere, cylinder, spherical equivalent (SE), axis, and corrected distance visual acuity (CDVA) were compared pre- and postoperatively in 683 eyes of 548 patients at one month (n = 605 eyes) and one year (n = 211 eyes). Patients with both one-month and one-year follow-ups (n = 133) were also compared. Eyes were stratified into single-piece (n = 330), three-piece (n = 30), and light adjustable lenses (LALs) (n = 16). Pre- and postoperative measurements were analyzed within each group. Results Cylinder was significantly decreased at one-month (difference: 0.042±0.448 D, p = 0.006) and one-year (difference: 0.101±0.455 D, p = 0.003) compared to preoperative measurements. No significant change in sphere or axis was observed at follow-up visits (p > 0.05). CDVA significantly improved at both time points (p < 0.05). No significant change in any parameters between the one-month and one-year groups was observed (p > 0.05). There was significant improvement in CDVA in the single and three-piece lens groups (p < 0.0001 and p = 0.026, respectively), with no change in the LAL group (p > 0.05). Conclusion There were no changes in sphere, axis, or spherical equivalent after Nd:YAG capsulotomy. However, cylindrical error and CDVA were significantly better after the procedure. Lens type did not impact refractive parameters postoperatively.
Lipid keratopathy (LK) is a rare disease involving lipid deposition in the cornea resulting in corneal opacification. Primary LK can arise sporadically while secondary LK is seen in patients with a history of ocular trauma, medication exposure, infection, inflammation, or disorders resulting in derangements of lipid metabolism. Secondary LK is more common and occurs due to neovascularization. Use of precipitating medications should be considered in LK workup, particularly for patients in whom other etiologies have been ruled out. Brimonidine, an ocular hypotensive medication, can be associated with LK. We present a case of bilateral secondary LK in a patient with a history of prolonged brimonidine use, without additional contributing factors.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.